2 485 pass-through – db-9f connector, 3 remote control connector – db-9m connector – Mocomtech CRS-300 User Manual

Page 170

Advertising
background image

CRS-300 1:10 Redundancy Switch

Revision 16

Connector Pinouts

MN/CRS300.IOM

6–2

6.1.2

485 Pass-Through – DB-9F Connector

Table 6-1 indicates the pinout for the DB-9F 485 Pass-Through connector,
used only with the CDM-Qx/QxL modems.


Table 6-1. 485 Pass-Through User Data Connector

Pin

Description

Direction

1 Ground

2

EIA-232 Transmit Data

Out

3

EIA-232 Receive Data

In

4

Reserved - do not connect to this pin

5 Ground

6

EIA-485 Receive Data B (see note)

In

7

EIA-485 Receive Data A (see note)

In

8

EIA-485 Transmit Data B

Out

9

EIA-485 Transmit Data A

Out

Note: Use for 2-wire EIA-485 operation.

6.1.3

Remote Control Connector – DB-9M Connector

The DB-9M Remote Control connector provides access to the remote
control ports of the Switch, both EIA-232 and EIA-485. Table 6-2
provides the pinout information.


Table 6-2. Remote Control Connector

Pin

Description

Direction

1 Ground

2

EIA-232 Transmit Data

Out

3

EIA-232 Receive Data

In

4

Reserved - do not connect to this pin

5 Ground

6

EIA-485 Receive Data B (see note)

In

7

EIA-485 Receive Data A (see note)

In

8

EIA-485 Transmit Data B

Out

9

EIA-485 Transmit Data A

Out

Note: Use for 2-wire EIA-485 operation.