2 switch-to-switch connections, 1 crs300 to crs280/280l connection, 2 crs300 to crs350 connection – Mocomtech CRS-300 User Manual

Page 64: 3 crs300 to crs350 and crs280/280l connection

Advertising
background image

CRS-300 1:10 Redundancy Switch

Revision 16

Cables and Connections

MN/CRS300.IOM

4–4

4.2

Switch-to-Switch Connections

If the User’s redundancy system requires the Comtech EF Data CRS-280 (70/140 MHz) IF, CRS-
280L (L-Band) IF, and/or CRS-350 Engineering Service Channel (ESC) Switch (used only with
the CDM-600/600L, CDM-625, or SLM-5650/5650A), Control/Data Cable CA/WR0066 is
needed to connect the Switches. Each CRS-280/280L and CRS-350 is supplied with this cable for
connection to the associated Switch control unit.

The following sections outline the switch-to-switch cable connections between the CRS-300,
CRS-350, and the CRS-280/280L.

4.2.1

CRS-300 to CRS-280/280L Connection

Refer to Figure 4-1 and Figure 4-2 to connect and secure the CA/WR0066 cable between the
CRS-300 and the CRS-280/280L as follows:

• DB-25M connector labeled “IF Switch Control” on the CRS-300’s CRS-230 System

Controller, to

• DB-25F connector on the rear panel of the CRS-280/280L.

4.2.2

CRS-300 to CRS-350 Connection

Refer to Figure 4-3 to connect and secure the CA/WR0066 cable between the CRS-300 and the
CRS-350 as follows:

• DB-25M connector labeled “IF Switch Control” on the CRS-300’s CRS-230 System

Controller, to

• DB-25F connector on the rear panel of the CRS-350.

4.2.3

CRS-300 to CRS-350 and CRS-280/280L Connection

Refer to Figure 4-4 or Figure 4-5 to first connect and secure the CA/WR0066 cable between the
CRS-300 and CRS-350 as follows:

• DB-25M connector labeled “IF Switch Control” on the CRS-300’s CRS-230 System

Controller, to

• DB-25F connector on the rear panel of the CRS-350.

Next

, connect and secure the second 25-pin CA/WR0066 cable between the CRS-350 and

CRS-280/280L as follows:

• DB-25M connector on the CRS-350, to
• DB-25F connector on the rear panel of the CRS-280/280L.





Advertising