Mocomtech CRS-300 User Manual

Page 196

Advertising
background image

CRS-300 1:10 Redundancy Switch

Revision 16

Front Panel Operation

MN/CRS300.IOM

7–16

The three-letter instruction code is indicated also to assist decoding the following problem
parameters:

For the CDM-600L modem, the code is the hex value of the position of the problem

parameter within the MGC configuration code.

00

NO ERROR

01

TFQ

Tx Frequency

09

TDR

Tx Data Rate

12

TFT

Tx FEC Type

13

TRS

Tx Reed Solomon type

14

TCR

Tx FEC Code Rate

15 TMD Tx

Modulation

16 TSI Tx

Spectrum

Inversion

17

TSC

Tx Scrambler state

18

TPL

Tx Power Level

1C AUP AUPC

enable

1D APP AUPC

parameters

23

TCK

Tx Clock source

24

TXO

Tx Carrier state

25 TIT Tx

Interface

Type

26 TTC Tx

Ternary

Code

27

TFM

Tx Framing Mode

28

TIP

Tx IF Impedance

29

RFQ

Rx Frequency

31

RDR

Rx Data Rate

3A

RFT

Rx FEC Type

3B

RRS

Rx Reed Solomon type

3C

RCR

Rx FEC Code Rate

3D

RMD

Rx Modulation

3E

RSI

Rx Spectrum Inversion

3F

RDS

Rx DeScrambler state

40

RSW

Rx Sweep Width

42

RCK

Rx Clock source

43

EBA

EbNo Alarm point

47

RBS

Rx Buffer Size

4C

RIT

Rx Interface Type

4D

RTC

Rx Ternary Code

4E

RFM

Rx Framing Mode

4F

RIP

Rx IF Impedance

50

EFM

Unit EDMAC Mode

51

ESA

EDMAC Slave Address

55

TST

Unit Test Mode

56

MSK

Unit Alarm Mask

5C

EFR

External Freq Ref

5D

SSI

Statistics Sampling Interval

5E

RTE

Rx Terrestrial Alarm Enable

5F

TTA

Tx Terrestrial Alarm Mask

60

ODU

ODU comms Enable

61

TBA

Tx Backward Alarms

65

RBA

Rx Backward Alarms

69

TVL

Tx audio Volume

6D

RVL

Rx audio Volume

71

DTY

Drop Type

72

ITY

Insert Type

73

TET

Tx ESC Type - 64k or 2 audio

74

RET

Rx ESC Type - 64k or 2 audio

75

ITD

Invert Tx Data

76

IRD

Invert Rx Data

For the CDM-570L modem, the code is the decimal number indicating the problem

parameter within its MGC configuration code:

00

NO

ERROR

01 ITF Interface

02

LBO

T1 Line Build-Out

03

FRM

Framing mode

04

TFQ

Tx Frequency

05

TFT

Tx FEC Type

06

TMD

Tx Modulation

07

TCR

Tx FEC Code Rate

08

TDR

Tx Data Rate

09

TSI

Tx Spectrum Invert

10

TSC

Tx Scrambler state

11

TPL

Tx Power Level

12

TCK

Tx Clock

13

TDI

Tx Data Invert

14

TXO

Tx Carrier State

15

AUP

AUPC enable

16

APP

AUPC parameters

17

WUD

Warm-Up Delay

18

RFQ

Rx Frequency

19

RFT

Rx FEC Type

20

RMD

Rx Modulation

21

RCR

Rx FEC Code Rate

22

RDR

Rx Data Rate

23

RSI

Rx Spectrum Invert

24

RDS

Rx DeScrambler state

25

RDI

Rx Data Invert

26

RSW

Rx Sweep Width

27

EBA

Eb/No Alarm point

28

RBS

Rx Buffer Size/enable

29

ERF

External Reference setting

30

EFM

EDMAC Framing mode

31

ESA

EDMAC Slave Address range

32 TST Test

mode

33 MSK Alarm

Masks

34

RTS

Request-To-Send control

35

SSI

Statistics Sample Interval

Advertising