CRS-300 1:10 Redundancy Switch

Revision 16

Cables and Connections

MN/CRS300.IOM

4–28

Then,

connect and secure the Control/Data Cable CA/WR0066 (for data purposes) between the

TMI(s) and Traffic CDM-625(s) as follows make all connections as follows:

• DB-25M connector labeled “P1” on the TMI(s), to
• DB-25F connector labeled “Data Interface” on the Traffic CDM-625(s).

4.5.3.7 Quad E1 Data Connections

If Quad E1 is the driving traffic data type (refer to Figure 4-12

and Figure 4-13):

First,

connect the Control/Data Cable CA/WR0066 (for control purposes) between the Redundant

CDM-625 and the RMI (see Sect. 4.5.3.1).

Next,

connect and secure the Data ‘Y’ Cable CA-0000073 (DB-15F to <2X> DB-9M, 6’) between

the Redundant CDM-625 and the CRS-300 as follows:

• DB-15M connector labeled “P2” on the RMI, to
• DB-9F connector labeled “Balanced G.703” on the Redundant CDM-625 (using “P3”

connector on cable),

and

• DB-9F connector labeled “Aux G.703” on the Redundant CDM-625 (using “P2”

connector on cable).

Then,

connect and secure the Control Cable CA-0000069 (HD-15M to DB-9M, 6’) between the

CRS-365D

TMI(s) and Traffic CDM-625(s) as follows:

• HD-15F connector labeled “J1” on the TMI(s), to
• DB-9F connector labeled “1:1 Control” on the Traffic CDM-625(s).

Finally,

connect and secure a pair of Data Cables CA-0000136 (DB-9F to DB-9M, 6’) as

follows:

• DB-9M connector labeled “P1” on the TMI(s), to
• DB-9F connector labeled “Aux G.703” on the Traffic CDM-625(s),

and

• DB-9M connector labeled “P2” on the TMI(s), to
• DB-9F connector labeled “Balanced G.703” on the Traffic CDM-625(s).