Moog RKP-II User Manual

Page 28

Advertising
background image

Compensator Operation

3 Product Description

20 User Manual RKP-II (CA53461-001; Version 2, January 2010) © 2010 Moog GmbH

3.5.5 Load Sensing Compensator with p-T Control
Notch, R1

Load Sensing
Compensator with p-T
Control Notch, R1

Metering orifice:
Manually remote adjustable orifice valve or proportional orifice valve.

Pressure pilot valve:
Manually remote adjustable proportional pressure valve Q = 1–1.5 l/min.
For multiple pumps feeding in one common line, only one compensator with a
p-T control notch may be used. This compensator must be set to the higher

Δp

value.

Fig. 9: Load Sensing Compensator with p-T Control Notch, R1

Pos.

Description

Pos.

Description

1

Metering orifice for flow control

8

Δp spring

2

Safety valve p = p

max.

+ 30 bar

9

Locked adjustment screw

3

Control piston 2

10

Orifice Ø 0.8 ... 0.9mm

4

Control piston 1

11

Locknut for the adjustment screw

5

Adjustment of zero stroke

12

Set at pilot valve

6

Pilot pressure valve:

13

Set at metering throttle

7

Valve spool