Preserving the Pump

5 Transport and Storage

32 User Manual RKP-II (CA53461-001; Version 2, January 2010) © 2010 Moog GmbH

Procedure:

1. Inspect to assure that all openings have been closed using flange covers

or caps.

2. Check to assure that transportation protection means are attached to the

pump's drive shaft.

3. Make certain that the storage space

- Is clean, dry, frost-protected and free of corrosives and vapors.

- Has a consistent temperature (temperature difference < 10 °C).

4. Depending on storage duration: preserve the pump

Ö Tab. 5, Page 31

5. Check the storage conditions

Ö Tab. 6, Page 31

6. After delivery: No steps need to be taken.

7. After demounting: Pour a small amount of mineral oil into the pump's

interior.

5.4 Preserving the Pump

Preserving the Pump

Pre-Conditions:

• Pump has been demounted.

Ö Chap. "9.1 Demounting the Pump", Page 55

• Pump is clean and dry.

• All openings are closed using flange covers or caps.

Procedure:

1. Apply corrosion preventative (Castrol SafeCoat DW 18X) evenly to the

pump's exterior surface.

2. Allow the pump to dry.

The pump should only be preserved on the exterior.

WARNING

Damage to Property!
Improper preservation or no preservation at all may cause
corrosion to the pump.

• If required, properly preserve the pump

Ö Chap. " Preservation Conditions", Page 31

Before the initial set-up of the pump, it does not need to be de-preserved.