Arranging Multiple Pumps

6 Mounting

40 User Manual RKP-II (CA53461-001; Version 2, January 2010) © 2010 Moog GmbH

6.6.2 Attaching the Adapter Flange

Pre-Conditions:

Attaching the Adapter
Flange

• The centering diameters of both the adapter flange and the add-on pump

match.

• The dimensions of the through drive shaft match with the add-on pump.

• The flange diameters of both the adapter flange and the add-on pump

match.

• The connection surfaces are clean.

Procedure:

1. Attach the adapter flange to the add-on pump without damaging the

O-rings.

2. Bolt the adapter flange to the pump:

- Observe the tightening torques of the fasteners.

Ö Chap. "12.2 Tightening Torque", Page 63

For adding on a pump, the following adapter flanges are available:

Adapter flange SAE-A with 9-tooth shaft

Fig. 22: Adapter flange SAE-A with 9-tooth shaft

The adapter includes through drive shaft, seals (HNBR), intermediate ring for
RKP 63–140 and two fastening screws.

Profile

Thread

Shaft end

Thread

for add-on pump

Bolt

Flange Code:

82-2

Shaft Code:

16-4

Spline as per:

ANSI B92.1 9T 16/32 DP Flat root side fit

Conditions for
attachment:

RKP with heavy-duty through drive