7 Operation

Initial Pump Set-Up

© 2010 Moog GmbH User Manual RKP-II (CA53461-001; Version 2, January 2010) 45

7.1.2.1 Hydraulically Driven Remote Pressure
Compensator, H1

Default Compensator Settings

Δp = 10 bar + 2 bar or Δp = 20 bar + 2 bar

Hose for Control Line

The following information are recommended values:

Hose length approx. 800 mm

7.1.2.2 Load Sensing Compensator with p-T Control
Notch, R1

Default Compensator Settings

RKP-II 16–100:

Δp = 10 bar + 2 bar

RKP-II 140:

Δp = 13 bar + 2 bar

Hose for Control Line

The following information provides recommended values:

Hose length approx. 800 mm

Information on the compensator:
Ö Chap. "3.5.2 Hydraulically Driven Remote Pressure Compensator, H1",
Page 17

The information in this section also applies to:

Ö Chap. "3.5.4 Load Sens-

ing Compensator, J1", Page 19

When high dynamics are required for flow control, orifice and control flow
volume, contact us to discuss application specific compensator
adjustments.

Pump Type

NW [mm]

RKP-II 19

6

RKP-II 32, 45

8

RKP-II 63, 80, 100

10

Tab. 8: Nominal width for Control Line Hose

Information on the compensator:
Ö Chap. "3.5.5 Load Sensing Compensator with p-T Control Notch, R1",
Page 20

Pump Type

NW [mm]

D1 [mm]

D2 [mm]

RKP-II 19, 32, 45

6

0.9

1.2

RKP-II 63, 80, 100

8

0.9

1.2

RKP-II 140

8

0.8

1.1

Tab. 9: Nominal width for Control Line Hose