7 Operation

Initial Pump Set-Up

© 2010 Moog GmbH User Manual RKP-II (CA53461-001; Version 2, January 2010) 47

7.1.2.4 Servo Control, C1

Fig. 25: Servo Control, C1

Procedure:

1. Regulate the pump's flow volume by positioning the adjustment lever.

Information about the Servo Control:
Ö Chap. "3.5.7 Servo Control, C1", Page 22

The zero position and the end position are set at the factory. Manual or
mechanical operations are performed using the adjustment lever.

Pos.

Description

1

Zero position (set at the factory)

2

End position / ±V

max.

(set at the factory)

Displacement V [cm

3

/R]

19

32

45

63

80

100

Angle

α [°]

44

47

57

44

56

56

Control torque M [Nm]

Zero position

1.2

1.6

End position

1.6

1.7

2.4

2.6

2.6

max.

8

Tab. 11: Adjustment Torque Servo Control