2 performing functions tests, 6 limiting the maximum flow – Moog RKP-II User Manual

Page 57

Advertising
background image

7 Operation

Performing Functions Tests

© 2010 Moog GmbH User Manual RKP-II (CA53461-001; Version 2, January 2010) 49

7.1.2.6 Limiting the Maximum Flow

Fig. 27: Limiting the Maximum Flow

7.2 Performing Functions Tests

Performing Functions
Tests

Pre-Conditions:

• Initial set-up of the pump is complete:

Ö Chap. "7.1 Initial Pump Set-Up",

Page 43

• The end caps on the through drive of the pump stages have been

removed.

• It has been assured that the pump is being supplied with operating fluid.

• The pump has been visually inspected, with particular attention given to

the lines and port connections.

Procedure:

1. Carry out the functions test in accordance with the instructions provided

by the machine / equipment manufacturer.

Pos.

Description

1

Adjustment mandrel

2

Cap nut

3

Lock nut

Displacement
V [cm

3

/R]

19

32

45

63

80

100

140

Pos.1

WS 8

WS 12

WS 10

Pos. 2

WS 24 = 40 Nm +

10 Nm

WS 32 = 80 Nm +

10 Nm

WS 27 = 80 Nm +

10 Nm

Pos. 3

WS 24 = 50 Nm +

10 Nm

WS 32 = 90 Nm +

10 Nm

WS 27 = 90 Nm +

10 Nm

ΔV for 1 mm
adjusting
screw travel
(pitch
1.5 mm/R)

3.6

5.6

6.5

8.9

11.3

11.5

Tab. 13: Adjustments Limiting the Maximum Flow

The functions tests is performed to ensure that the pump has been
installed into the machine / equipment properly.

Advertising