Commands

7193 Owner’s Guide

May 1996

92

Hex

Decimal

ASCII

Value of n

10 04 n

16 4 n

DLE EOT n

1 = Transmit printer status
2 = Transmit RS-232C busy status
3 = Transmit error status
4 = Transmit receipt paper status
5 = Transmit slip paper status

The command is ignored if n is out of range.

Note:

An application using the DLE sequence must send EOT within 100

milliseconds of DLE or the printer will misinterpret the DLE and execute a
Clear Printer command. Avoid this possibility by using the GS EOT n
sequence which is handled exactly the same as DLE EOT n.

1 = Transmit Printer Status

Bit

Status

Hex

Decimal

Function

0

Off

00

0

Fixed to Off

1

On

02

2

Fixed to On

2

Off
On

00
04

0
4

One or both cash drawers open
Both cash drawers closed

3

Off
On

00
08

0
8

Not busy at the RS-232C interface
Printer is Busy at the RS-232C interface

4

On

10

16

Fixed to On

5

Undefined

6

Undefined

7

Off

00

0

Fixed to On