7.8 Composite Link Settings - External Device

Table 7-8. Composite Link Settings - External Device

Step

Procedure

1

Toggle DIP switch position 3 to the down (closed) position to enable the command port.

2

Connect a terminal or PC running communications software to the DATA/COMMAND
connector on the back panel of the DataTalker.

Note:

Any cables connected to the computer should be shielded to reduce interference.

3

Apply power to the DataTalker.

4

Apply power to the terminal or PC. Run the PC’s communications software in terminal mode
and press ENTER twice to establish communications with the DataTalker. The Main Menu
appears:

Main Menu

1 - Configurations
2 - Statistics
3 - Reset Options
4 - Diagnostics
5 - Exit Command Mode
6 - QUICK SETUP

Selection : _

5

Enter 1 and press ENTER. The Configurations menu is displayed:

Configurations

1 - Data Port Configuration
2 - Voice/Fax Channel(s) Configuration
3 - Composite Link Configuration
4 - Factory Default Configuration Options
5 - Configure Remote Unit
S - Store All Configurations
M - Main Menu
P - Previous Menu

Selection : _

6

Enter number 3 from the configurations menu and press ENTER to display the Composite
Link Settings - External Device menu.

7

Verify the external device settings. To change settings, enter the appropriate option numbers.

C o m p o s i t e L i n k S e t t i n g s - E x t e r n a l D e v i c e

1 - O n - L i n e X M T R a t e : 5 6 0 0 0
2 - C l o c k i n g : E x t e r n a l
3 - B a c k t o B a c k : O f f
4 - D O D / D O I : O n
5 - D O I T i m e r : 0 3 m i n
6 - D O D T o g g l e D T R : 4 0 s e c
S - S t o r e A l l C o n f i g u r a t i o n s
M - M a i n M e n u
P - P r e v i o u s M e n u
S e l e c t i o n : _

8

When all the options for the external device are set, enter S and press ENTER to store all
configurations. Then enter M and press ENTER to return to the Main Menu.

9

Disconnect the terminal or PC from the command port and place DIP switch position 3 in the
up (OPEN) position to change the command/data port over to a data channel.