DataTalker Owner’s Manual

92

Table 7-2.

Composite Link Troubleshooting Internal DSU

Problem

Composite link down with CD,
CTS, XMT, RD and RCV LEDs
on

Flashing RXT LED

Possible Causes

Composite link not configured
correctly

High error rate on communication
line

DSU clocking configured
incorrectly

Solution

1.

Verify DSU configuration. See
Composite Link settings -
Inernal DSU in Table 7-5.

2.

Call Tech Support for
assistance (see Chapter 8).

1.

View composite link statistics
(refer to Table 7-10).

2.

Perform composite link
loopback tests (refer to Table
7-12).

3.

Call phone company and
verify communication line.

4.

Call Tech Support for
assistance (see Chapter 8).

1.

For DDS line, both DSUs
should be set for DDS
clocking.

2.

Call phone company and
verify communication line.

3.

Call Tech Support for
assistance (see Chapter 8).