Chapter 7 - Troubleshooting

Table 7-1.

Command Port Troubleshooting

Problem

Command port device not
communication with DataTalker

Possible Causes

Communications software not
installed on command port PC

Command port not enabled

Bad cable or cable connection

Solution

1.

Install communications
software on command port PC
(refer to communcations
software documentation of
installation instructions).

1.

Set DIP-Switch #3 to the
closed (down) position.

1.

Check RS-232 cable
connections between
command port device and
Command port on DataTalker
for loose connections or bent
pins.

2.

Check RS-232 cable
connections between
command port device and
Command port on DataTalker
for correct cable wiring (see
cabling diagrams in Appendix
C).

3.

Call Tech Support for
assistance (see Chapter 8).

Table 7-2.

Composite Link Troubleshooting Internal DSU

Problem

Composite link down with CTS,
XMT, and RD LED on

Possible Causes

DSU not communication with
communication line

Faulty communication line

Solution

Verify that the DSU LED is on. If
off, ensure that DIP-Switch #2 is in
the open (up) position.

Verify that a cable is connected to
the internal composite DSU/TA
Digital connector.

Verify DSU configuration. See
Composite Link Settings - Internal
DSU in Table 7-5.

Call Tech Support for assistance
(see Chapter 8).

Call phone company and verify
communication line.

Call Tech Support for assistance
(see Chapter 8).