Multi-Tech Systems DataTalker DT101/xx User Manual

Page 93

Advertising
background image

93

Chapter 7 - Troubleshooting

Internal ISDN Terminal Adapter

Problem

Composite link down with CTS,
XMT and RD LEDs on

Composite link down with CD,
CTS, XMT, RCV and RD LEDs
on

Flashing RXT LED

Possible Causes

Terminal adapter not
communicating with ISDN line

Faulty communication line

Composite link not configured
correctly

High error rate on communication
line

ISDN clocking configured
incorrectly

Solution

1.

Verify that the the TA LED is
on. If off, ensure that DIP-
Switch #2 is set to OPEN
(Up).

2.

Verify that a cable is
connected to the internal
composite DSU/TA Digital
connector.

3.

Verify ISDN configuration. See
Composite Link Settings -
Internal ISDN in Tabe 7-6.

4.

Call Tech Support for
assistance (see Chapter 8).

1.

Call phone company and
verify communication line.

2.

Call Tech Support for
assistance (see Chapter 8).

1.

Verify ISDN configuration, See
Composite Link Settings -
Internal ISDN in Table 7-6.

2.

Call Tech Support for
assistance (see Chapter 8).

1.

View composite link statistics
(refer to Table 7-9).

2.

Perform composite link
loopback tests (see
Diagnostic Testing in Table 7-
12).

3.

Call phone company and
verify communication line.

4.

Call Tech Support for
assistance (see Chapter 8).

1.

For ISDN line, both terminal
adapters should be set for
normal clock source.

2.

Call Phone company and
verify communication line.

3.

Call Tech Support for
assistance (see Chapter 8).