Internal MMH2834 Modem

Problem

Composite link down with CTS,
XMT, and RD LEDs on

Composite link down with CD,
CTS, XMT, RCV and RD LEDs
on

Flashing RXT LED

Possible Causes

MMH2834 modem not
communicating with
communications line

Faulty communications line

Composite link not configured
correctly

High error rate on communication
line

Solution

1.

Verify MDM LED is on. If off,
ensure that DIP-Switch #2 is
in the OPEN (Up) position.

2.

Verify that cables are
connected to internal
composite Modem Dial-up or
Leased connector.

3.

Verify modem configuration
(see Composite Link Settings
- Internal MMH2834 in Table
7-7).

4.

Perform Local Analog
Loopback test (see Appendix
G, “Testing your MMH2834”).

5.

Call Tech Support for
assistance (see Chapter 8).

1.

Call phone company and
verify communication line.

2.

Call Tech Support for
assistance (see Chapter 8).

1.

Verify modem configuration
(see Composite Link Settings
- Internal MMH2834 in Table
7-7).

2.

Call Tech Support for
assistance (see Chapter 8).

1.

View composite link statistics
(refer to Table 7-9).

2.

Perform Local Analog
Loopback test (see Appendix
G, “Testing your MMH2834”).

3.

Call phone company and
verify communication line

4.

Call Tech Support for
assistance (see Chapter 8).