12 diagnostic testing, Diagnostic testing, Table 7-12. diagnostic testing – Multi-Tech Systems DataTalker DT101/xx User Manual

Page 109

Advertising
background image

109

Chapter 7 - Troubleshooting

7.12 Diagnostic Testing

Table 7-12. Diagnostic Testing

Step

Procedure

1

Toggle DIP switch position 3 to the down (closed) position to enable the command port.

2

Connect a terminal or PC running communications software to the DATA/COMMAND
connector on the back panel of the DataTalker.

Note:

Any cables connected to the computer should be shielded to reduce interference.

3

Apply power to the DataTalker.

4

Apply power to the terminal or PC. Run the PC’s communications software in terminal mode
and press ENTER twice to establish communications with the DataTalker. The Main Menu
appears:

Main Menu

1 - Configurations
2 - Statistics
3 - Reset Options
4 - Diagnostics
5 - Exit Command Mode
6 - QUICK SETUP

Selection : _

5

Enter 4 and press ENTER. The Diagnostics menu is displayed:

Diagnostics

1 - Loop Test

2 - Memory Test

3 - Watch Dog Test

4 - Dip Switch Definitions and Settings

5 - Product and Firmware ID

M - Main Menu

P - Previous Menu

Selection : _

6

Select the test you wish to run by entering its option number and pressing ENTER.

If you select Loop Test, the Loop Test menu will appear.

Advertising