7.7 Composite Link Settings - Internal Modem

Table 7-7. Composite Link Settings - Internal MMH2834

Step

Procedure

1

Toggle DIP switch position 3 to the down (closed) position to enable the command port.

2

Connect a terminal or PC running communications software to the DATA/COMMAND
connector on the back panel of the DataTalker.

Note:

Any cables connected to the computer should be shielded to reduce interference.

3

Apply power to the DataTalker.

4

Apply power to the terminal or PC. Run the PC’s communications software in terminal mode
and press ENTER twice to establish communications with the DataTalker. The Main Menu
appears:

Main Menu

1 - Configurations
2 - Statistics
3 - Reset Options
4 - Diagnostics
5 - Exit Command Mode
6 - QUICK SETUP

Selection : _

5

Enter 1 and press ENTER. The Configurations menu is displayed:

Configurations

1 - Data Port Configuration
2 - Voice/Fax Channel(s) Configuration
3 - Composite Link Configuration
4 - Factory Default Configuration Options
5 - Configure Remote Unit
S - Store All Configurations
M - Main Menu
P - Previous Menu

Selection : _

6

Enter 3 and press ENTER to display the Composite Link Settings - Internal MMH2834 menu.

7

Verify the internal MMH2834 modem settings. To change settings, enter the appropriate
option numbers.

Composite Link Settings - Internal MMH2834

1 - Enter AT commands to 2834
2 - On-Line XMT Rate: 28800
3 - Speed Setting: 33600
4 - Dial/Leased: Dial
5 - 2 or 4 Wire: 2 Wire
6 - Answer/Originate: Answer
7 - Transmit Level -10db
8 - DOD/DOI: On
9 - DOI Timer: 03min
10 - DOD Toggle DTR: 40sec
S - Store All Configurations
M - Main Menu
P - Previous Menu
Selection : _

8

When all options for the port and modem are set, enter S and press ENTER to store all
configurations. Then enter M and press ENTER to return to the Main Menu.

9

Disconnect the terminal or PC from the command port and place DIP switch position 3 in the
up (OPEN) position to change the command/data port over to a data channel.