Chapter 7 - Troubleshooting

7.10 Data Port Configuration

Table 7-10. Data Port Configuration

Step

Procedure

1

Toggle DIP switch position 3 to the down (closed) position to enable the command port.

2

Connect a terminal or PC running communications software to the DATA/COMMAND
connector on the back panel of the DataTalker.

Note:

Any cables connected to the computer should be shielded to reduce interference.

3

Apply power to the DataTalker.

4

Apply power to the terminal or PC. Run the PC’s communications software in terminal mode
and press ENTER twice to establish communications with the DataTalker. The Main Menu
appears:

Main Menu

1 - Configurations
2 - Statistics
3 - Reset Options
4 - Diagnostics
5 - Exit Command Mode
6 - QUICK SETUP

Selection : _

5

Enter 1 and press ENTER. The Configurations menu is displayed:

Configurations

1 - Data Port Configuration
2 - Voice/Fax Channel(s) Configuration
3 - Composite Link Configuration
4 - Factory Default Configuration Options
5 - Configure Remote Unit
S - Store All Configurations
M - Main Menu
P - Previous Menu

Selection : _

6

Enter 1 and press ENTER to display the Data Port Configuration menu.

Data Port Configuration

1 - Async/Sync: Async
2 - Speed: 19200
3 - Word Length: 8
4 - Stop Bits: 1
5 - Parity: None
6 - Flow Control: CTS
7 - Enq/Ack Flow Control: Off
8 - Echo: Off
9 - Pacing: Off
10 - EIA Pass Through: Off
11 - Pass Xon: Off
S - Store All Configurations
M - Main Menu
P - Previous Menu
Selection : _