5.1 Introduction

This chapter describes how to connect the DataTalker to your system (Table 5-1) and how to
move the RS232/V.35 shunt when a V.35 interface is used (Table 5-2). Then it describes how to
power on your DataTalker, check that the unit is cabled and configured correctly, and what to do if
you run into problems.

5.2 Cabling

Connecting the DataTalker to your system requires two to four cables, depending on how you
intend to use the DataTalker. Each cable connection will be explained in detail in the following
procedures. When you cable the unit, you should consider how you configured it in Chapter 4.
For instance, if you configured the unit for a sync data channel, you cannot connect a standard
RS232C cable to the DATA/COMMAND connector on the back of the DataTalker. The following
cabling procedures relate the cables to the configuration.

Table 5-1. Cabling Procedure

Step

Procedure

Composite Link

1

Verify that DIP switch position 2 is set for the composite link device being used:

Device

DIP Switch 2

Internal

OPEN (Up)

External

Closed (Down)

MODEM

DSU/TA

DIAL-UP

LEASED

DIGITAL

VOICE/FAX CHANNEL 1

FXO

FXS

EXTERNAL COMPOSITE

DATA/COMMAND

RS232C/V.35

E&M

INTERNAL COMPOSITE

POWER

GND

DIP
Switch

Figure 5-1. DIP Switches

2

If you are using your DataTalker with an internal composite link device, connect one of the
two phone cables supplied with your unit to the appropriate internal composite connector:

MMH2834 Modem, Dial-up

Connect the RJ-11 phone cable supplied with the DataTalker from the internal modem DIAL-
UP jack on the back panel to the dial-up line jack.

MODEM

DSU/TA

DIAL-UP

LEASED

DIGITAL

VOICE/FAX CHANNEL 1

FXO

FXS

EXTERNAL COMPOSITE

DATA/COMMAND

RS232C/V.35

E&M

INTERNAL COMPOSITE

POWER

GND

Internal Modem
DIAL-UP Connector

RJ-11 Phone Cable

Figure 5-2. Dial-Up Line Connection