3 v.35 shunt, V.35 shunt, Table 5-2. v.35 shunt procedure – Multi-Tech Systems DataTalker DT101/xx User Manual

Page 60

Advertising
background image

60

DataTalker Owner’s Manual

5.3 V.35 Shunt

Table 5-2. V.35 Shunt Procedure

Step

Procedure

1

Desktop version: Unplug the power supply from the back of the unit.

Rack version: Remove the unit from the RackTalker rack. Go to step 4.

2

Desktop version only: Turn the unit upside down and remove the two cabinet mounting
screws from the middle of the cabinet.

Cabinet
Mounting
Screws (2)

COMPOSITE

LINK

STATUS

VOICE /

FAX 1

DATA/

COMMAND

ORIG

101 MDM / TA

RXT

FCR

RD

TM

V35

EXT

MDM

DSU

CD

RCV

XMT

CTS

56

RTS

NS

OOS

28.8

OH

DBUP

TA

DTR

2B

COM

XMT

RCV

FC

FXS

FXO

E&M

FAX

XMT

RCV

XSG

RSG

VOICE /

FAX 2

RSG

XSG

RCV

XMT

FAX

E&M

FXO

FXS

Data / Voice / Fax Concentrator

Figure 5-11. Cabinet Mounting Screws

3

Desktop version only : Turn the cabinet right-side up, tilt the back down slightly, and the base
unit will slide out of the cabinet.

4

Desktop and rack versions: Place the unit with the LEDs facing you.

5

Pry the shunt out of the RS232 socket and insert it into the V.35 socket. Rack version: Go to
step 8.

1 2 3 4 5 6

RS-232
Shunt

V.35
Shunt

Figure 5-12. V.35 Shunt Location (Desktop Version)

6

Desktop version only: Slide the base back into the cabinet with the LEDs toward the front and
the rear grounding tabs pressing against the side of the cabinet.

7

Desktop version only: Turn the unit upside down and replace the two cabinet mounting
screws.

8

Desktop version: Turn the unit right-side up and reconnect the power supply.

Rack version: Slide the unit into the RackTalker card guides and, after ensuring that the
DataTalker is fully seated, fasten the retaining screws.