4 power-on and checkout, Power-on and checkout, Table 5-3. power-on and checkout procedure – Multi-Tech Systems DataTalker DT101/xx User Manual

Page 61: 61 chapter 5 - installation

Advertising
background image

61

Chapter 5 - Installation

5.4 Power-On and Checkout

The desktop and rack-mounted versions of the DataTalker differ in how power is applied. The
desktop version has a power switch that you must turn on. The rack version has no power
switch; you apply power by inserting it into a powered-up rack. It is always on as long as the rack
is powered up.

Table 5-3. Power-On and Checkout Procedure

Step

Procedure

1

Desktop version: Ensure that the power supply is connected to the unit’s power connector
and an AC outlet.

Rack version: Ensure that the DataTalker is properly seated in a RackTalker rack. Tighten the
front panel screws to ensure a good connection with the RackTalker power bus.

2

Desktop version: Apply power (press the power switch on the back of the unit to I [on]).

Rack version: Plug the RackTalker rack into an AC outlet, if it is not already powered up.

MODEM

DSU/TA

DIAL-UP

LEASED

DIGITAL

VOICE/FAX CHANNEL 1

FXO

FXS

EXTERNAL COMPOSITE

DATA/COMMAND

RS232C/V.35

E&M

INTERNAL COMPOSITE

POWER

GND

Power
Switch

Figure 5-13. Power Switch (Desktop Version)

3

Verify the states of the following composite link LEDs. The LED should be on for each
installed feature and off for each uninstalled feature:

Composite Link Device

LED

Internal 28.8K bps modem

MDM

Internal 56K DSU

DSU

Internal ISDN terminal adapter

TA

External modem, DSU, or TA

EXT

External V.35 interface

V35

COMPOSITE

LINK

STATUS

VOICE /

FAX 1

DATA/

COMMAND

ORIG

101 MDM/TA

RXT

FCR

RD

TM

V35

EXT

MDM

DSU

CD

RCV

XMT

CTS

56

RTS

NS

OOS

28.8

OH

DBUP

TA

DTR

2B

FXS

FXO

E&M

FAX

XMT

RCV

XSG

RSG

COM

XMT

RCV

FC

VOICE /

FAX 2

RSG

XSG

RCV

XMT

FAX

E&M

FXO

FXS

Data / Voice / Fax Concentrator

Figure 5-14. Front Panel

4

Establish a link with the remote DataTalker if the local DataTalker is not configured to link
automatically.

5

Verify that the composite link is communicating with the remote DataTalker. The RD LED
should be off. The following LEDS should be on:

Terminal adapter:

CD, RCV, XMT, CTS, DTR, and 2B (if so configured)

Modem:

CD, RCV, XMT, CTS, and DTR

DSU:

CD, RCV, XMT, CTS, and RTS

Advertising