Milwaukee LSM40MP-2 User Manual

Page 11

Advertising
background image

NOTE:.DIAGRAMS.&.ILLUSTRATIONS.ARE.NOT.TO.SCALE.

11

C

Back wall of chase/enclosure

(including any finishing materials)

D

A

B

Model

No.

A

B

C

D

LSM40-2

in.

50-5/8

83-5/8

59-1/8

41-7/8

mm

1286

2124

1502

1064

LSM45-2

in.

56-3/4

89-7/8

63-1/2

44-7/8

mm

1441

2283

1613

1140

Figure 13 - Corner Framing with Square Termination (SV8HTS)

Schedule 40

Black Iron Pipe

Inside Diameter (Inches)

Schedule 40 Pipe

Length (feet)

Natural

Gas

Propane

Gas

0-10

1/2

3/8

10-40

1/2

1/2

40-100

1/2

1/2

100-150

3/4

1/2

150-200

3/4

1/2

Table 6

Proper Sizing of Gas Line

Properly. size. and. route. the. gas. supply. line.

from.the.supply.regulator.to.the.area.where.the.

appliance.is.to.be.installed.per.requirements.

outlined.in.the.National.Fuel.Gas.Code,.NFPA.

54.-.latest.edition.(USA).or.CAN/CSA-B149.1.

-.latest.edition.(Canada)..

Notes:

•. All. appliances. are. factory-equipped. with.

a.flexible.gas.line.connector.and.1/2.inch.

shutoff.valve.(see.

Figure 37.on.Page 22).

•. See.

Massachusetts Requirements.on.Page

4..for.additional.requirements.for.installations.

in.the.state.of.Massachusetts.in.the.USA.

•. The.gas.supply.line.should.Not.be.connected.

to.the.appliance.until.

Step 6.(Page 22).

•. A.pipe.joint.compound.rated.for.gas.should.be.

used.on.the.threaded.joints.

Ensure propane

resistant compounds are used in propane

applications..Be.very.careful.that.the.pipe.

compound.does.not.get.inside.the.pipe.

•. It.is.recommended.to.install.a.sediment.trap.

in.the.supply.line.as.close.as.possible.to.the.

appliance.(see.

Figure 37)...Appliances.using.

propane.should.have.a.sediment.trap.at.the.

base.of.the.tank.

•. Check.with.local.building.official.for.local.

code.requirements.(i.e..are.below.grade.pen-

etrations.of.the.gas.line.allowed?,.etc.).

IMPORTANT: If propane is used, be aware that

if tank size is too small (i.e. under 100-lbs, if

this is the only gas appliance in the dwelling.

Ref. NPFA 58), there may be loss of pressure,

resulting in insufficient fuel delivery (which

can result in sooting, severe delayed ignition

or other malfunctions). Any damage resulting

from an improper installation, such as this, is

not covered under the limited warranty.

Right Side

Front Corner

Of Fireplace

Framing

6-1/4”

(159 mm)

19-5/8”

(498 mm)

Figure 14

Step 2. ROUTING GAS LINE

Route.a.1/2".(13.mm).gas.line.along.the.inside.

of.the.right.side.framing.as.shown.in

Figure

14...Gas.lines.must.be.routed,.constructed.and.

made.of.materials.that.are.in.strict.accordance.

with.local.codes.and.regulations.

All. appliances. are. factory-equipped. with. a.

flexible.gas.line.connector.and.1/2.inch.shutoff.

valve..(See Step 6 on Page 22).

The. incoming. gas. line. should. be. piped. into.

the.valve.compartment.and.connected.in.one.

of.the.two.methods.as.shown.in.Figure 37.on.

Page 22.

Never. use. galvanized. or. plastic. pipe.. . Refer.

to.

Table 6.for.proper.sizing.of.the.gas.sup-

ply.line,.if.black.iron.pipe.is.being.used..Gas.

lines.must.be.routed,.constructed.and.made.

of.materials.that.are.in.strict.accordance.with.

local.codes.and.regulations....We.recommend.

that.a.qualified.individual.such.as.a.plumber.or.

gas.fitter.be.hired.to.correctly.size.and.route.

the.gas.supply.line.to.the.appliance..Installing.

a.gas.supply.line.from.the.fuel.supply.to.the.

appliance.involves.numerous.considerations.of.

materials,.protection,.sizing,.locations,.controls,.

pressure,.sediment,.and.more..Certainly.no.one.

unfamiliar.and.unqualified.should.attempt.sizing.

or.installing.gas.piping.

Advertising