Horizontal terminations have been designed to perform in a wide range of weather condi-

tions. Our terminations meet or exceed industry standards.
When selecting the locations of your horizontal terminations, do not place the termina-

tion where water from eaves and adjoining rooflines may create a heavy flow of cascad-

ing water onto the termination cap. If the cap must be placed where the possibility of

cascading water exists, it is the responsibility of the builder to direct the water away

from the termination cap by using gutters or other means.
Take care to carefully follow the installation instructions for the termination, including

the use of silicone caulking where required.

Figure 29

Installing the Square Horizontal Termination (SV8HTS)

Firestop/Spacer (SV8HF) shown

on the exterior side of the wall. It

may also be installed on the

interior side.

SV8HTS

Termination

Shown.

13"

(330mm)

8 ¹⁄₂"

(216)

6 ¹⁄₂"

(165 mm)

15"

(381 mm)

Note: Centerline of Vent Piping is

NOT the Same as the Centerline of

the Framed Opening.

6 to 48 inch Vent Section,

Telescopic vent section.

See Figure 9 on page 7

for Min. Distance to Base

of Appliance.

Base of Appliance

3"

(76 mm)

Adapter

SV8RCH

1"

(25 mm)

1"

(25 mm)

Figure 30 - Wall Thickness and Horizontal Termination Requirements

u

For wall thicknesses greater than

8-1/2 inches, see Table 8

u

Siding

Stucco

1-1/4” Maximum Recess of

Square Termination into

Exterior Finishing Material

Exterior Surface of

Framing

5 in. to 8-1/2 in.

(127 to 216 mm)

Exterior Surface of Siding

Minimum wall thickness

5 in. (127 mm)

Interior Surface of

Finished Wall

Maximum wall thickness

8-1/2 in. (216 mm)

SV8HTS

Square Termination

shown

Maximum Extent of

Vent Run Sections

Relative to Exterior

Surface of Framing

Last Vent Section. Use

T e l e s c o p i c V e n t

Section (SV8LA), If

Necessary

Adapter

SV8RCH

SV8HTS

Square Termination

Shown

Venting Connection and Exterior Wall Recessing

of the Horizontal Square Termination (SV8HTS).

See Figure 12 on Page 10 for Minimum

Distance to Base of Appliance

J..Assemble vent run to exterior wall -.If.not.

previously.measured,.locate.the.center.of.the.

vent.at.the.exterior.wall...Prepare.an.opening.

as. described. in.

Step B.. . Assemble. the. vent.

system.to.point.where.the.terminus.of.the.last.

section.is.within.5.in..(127.mm).to.8-1/2.in..(216.

mm).inboard.of.the.exterior.surface.to.which.

the.SV8HTS.termination.is.to.be.attached,.see.

Figure 30 and Table 8...

If.the.terminus.of.the.last.section.is.not.within.

this.distance,.use.the.telescopic vent section

SV8LA, as.the.last.vent.section..For.wall.thick-

nesses.greater.than.that.shown.in.

Figure 30,.

refer.to.Table 8 on Page 19..This.table.lists.

the.additional.venting.components.needed.(in.

addition.to.the.termination.and.adaptor).for.a.

particular.range.of.wall.thicknesses.

K.. Attach termination adaptor -. Attach. the.

adaptor.(adaptor.-.SV8RCH.-.provided.with.the..

termination).to.the.vent.section.or.telescoping.

vent.section),.or.elbow.as.shown.in.Figure 29

in.the.same.manner.as.any.SV.vent.component.

(refer.to.Step E).

L.. Install Firestop/Spacer at exterior wall

-.When.using.the.square termination,.install..

SV8HF.Firestop/Spacer.over.the.opening.at.the.

exterior.side.of.the.framing,.long.side.up,.with.

the.3.inch.spacer.clearance.at.the.top.as.shown.

in.Figure 29,.and.nail.into.place.

(The. Firestop/Spacer. may. also. be. installed.

over. the. opening. at. the. interior. side. of. the.

framing).

M. Install the square termination (SV8HTS)-..

For. the. last. step,. from. outside. the. exterior.

wall,.slide.the.collars.of.the.termination.onto.

the.adaptor.(the.outer.over.the.outer.and.the.

inner. inside. the. inner). until. the. termination.

seats.against.the.exterior.wall.surface.to.which.

it.will.be.attached...Orient.the.housing.of.the.

termination.with.the.arrow.pointed.upwards...

Secure.the.termination.to.the.exterior.wall...The

horizontal termination must not be recessed

into the exterior wall or siding.by more than

the 1-1/4" (32 mm) as shown in.Figure 30.

IMPORTANT: The vent termination is hot

while in operation and for a period of time

following the use of the fireplace. Young

children should be carefully supervised

when they are in the same area as a hot

termination.