Milwaukee LSM40MP-2 User Manual

Page 8

Advertising
background image

8

NOTE:.DIAGRAMS.&.ILLUSTRATIONS.ARE.NOT.TO.SCALE.

*Note: 3 in. (75 mm) above any horizontal/inclined vent component.

**Note: See Page 9, Step 1 for clearance requirements to the nailing

flange located at each side of the unit and any screw heads adjacent

to it.

The.appliance.should.be.mounted.on.a.fully.supported.base.extending.

the.full.width.and.depth.of.the.unit..The.appliance.may.be.located.on.

or. near. conventional. construction. materials.. However,. if. installed. on.

combustible.materials,.such.as.carpeting,.vinyl.tile,.etc.,.a.metal.or.wood.

barrier.covering.the.entire.bottom.surface.must.be.used.

Shelf Height

To.provide.for.the.lowest.possible.shelf.surface,.the.venting.attached.to.

the.top.vent.should.be.routed.in.a.way.to.minimize.obstructions.to.the.

space.above.the.appliance...Do.not.insulate.the.space.between.the.ap-

pliance.and.the.area.above.it.(see.

Figure 8)..The.minimum.height.from.

the.base.of.the.appliance.to.the.underside.of.combustible.materials.used.

to.construct.a.utility.shelf.in.this.fashion.is.shown.in.

Figure 8.

Wall Finishes / Surrounds / Mantels

Note: Combustible wall finish materials and/or surround materials must

not be allowed to encroach the area defined by the appliance front face

(black sheet metal). Never allow combustible materials to be positioned

in front of or overlapping the appliance face. See Figure 10 and Figure

53 on Page 28.

Non-combustible.materials,.such.as.surrounds.and.other.appliance.trim,.

may.be.installed.on.the.appliance.front.face.with.these.exceptions:.they.

must.not.cover.any.portion.of.the.removable.glass.panel.

Vertical.installation.clearances.to.combustible.mantels.vary.according.

to.the.depth.of.the.mantel...See.

Figure 9..Mantels.constructed.of.non-

combustible.materials.may.be.installed.at.any.height.above.the.appliance.

opening.

NOTE: We recommend the use of high temperature paint (rated 175° F

or higher) on the underside of the mantel.

MINIMUM CLEARANCES TO COMBUSTIBLES

The.appliance.is.approved.with.zero.clearance.to.combustible.materials.on.

all.sides.(as.detailed.in.

Table 5),.with.the.following.exception:.When the

unit is installed with one side flush with a wall, the wall on the other

side of the unit must not extend beyond the front edge of the unit..In.

addition,.when.the.unit.is.recessed,.the.side.walls.surrounding.the.unit.

must.not.extend.beyond.the.front.edge.of.the.unit.(see.

Figure 3).

Figure 10

17"

14"

8-1/4”

45°

12"

5"

12 (305)

10 (254)

8 (203)

6 (152)

4 (102)

7

(178)

17

(432)

15

(381)

13

(330)

2 (51)

9

(229)

11

(279)

Figure 9

Combustible Materials

Allowed In Shaded Area

"Safe Zone"

Top View of

Fireplace

Minimum Distance to

Protected Side Wall

Minimum Distance to

Unprotected Side Wall

Side

Wall

Side

Wall

MANTEL

CLEARANCES

Inches (mm)

Top of Appliance

MANTEL

MANTEL

MANTEL

MANTEL

MANTEL

MANTEL

Fireplace

(side view)

Figure 8

APPLIANCE MINIMUM CLEARANCES*

Inches (millimeters)

Sides

1/2 (13), 0 (0) Spacers **

Top Spacers

0 (0)

Floor

0 (0)

Back

1/2 (13), 0 (0) Spacers

Bottom of Appliance To Ceiling

69 (1743)

Vent

3 (76)

Top

* / 1 (25.4)

Sides & Bottom

SERVICE CLEARANCES

Feet (meters)

Front

3 feet (0.9 meters)

Table 5

Combustible Shelf Height -

Inches (millimeters)

Top Vent - with 2 Feet Vertical Vent and One 90 Degree Elbow

Model

Secure Vent

LSM40-2

*84-1/16 (2135)

LSM45-2

89-1/16 (2252)

* Includes 3” clearance to combustibles (required above vent components)

Do not insulate the

space between the

appliance and the

area above it.

2 Foot Vertical

Vent (Min.)

Shelf Height

(see table)

Shelf Above Fireplace With Top Venting