NOTE:.DIAGRAMS.&.ILLUSTRATIONS.ARE.NOT.TO.SCALE.

These.appliances.must.be.isolated.from.the.

gas.supply.piping.system.(by.closing.their.

individual.manual.shut-off.valve).during.any.

pressure. testing. of. the. gas. supply. piping.

system. at. test. pressures. equal. to. or.

less

than.1/2.psig.(3.5.kPa).

These.appliances.and.their.individual.shut-off.

valves.must.be.disconnected.from.the.gas.

supply.piping.system.during.any.pressure.

testing.of.that.system.at.pressures.

greater

than.1/2.psig.(3.5.kPa).

Orifice Sizes - Sea Level To High Altitude

(All Models)

These.appliances.are.tested.and.approved.for.

installation.at.elevations.of.0-4500.feet.(0-1372.

meters). above. sea. level,. using. the. standard.

burner.orifice.sizes.(marked.with.an."*".in.Table

4)...For.elevations.above.4500.feet,.contact.your.

gas.supplier.or.qualified.service.technician.

Deration -. At. higher. elevations,. the. amount.

of.BTU.fuel.value.delivered.must.be.reduced.

by.either:

•.. Using.gas.that.has.been.derated.by.the.gas.

company..

•.. Changing.the.burner.orifice.to.a.smaller.size.

as.regulated.by.the.local.authorities.having.

jurisdiction.and.by.the.(USA).National.Fuel.

Gas. Code. NFPA. 54/ANSI. Z223.1. -. latest.

edition.or,.in.Canada,.the.CAN/CSA-B149.1.

codes.-.latest.edition.

Install.the.appliance.according.to.the.regulations.

of.the.local.authorities.having.jurisdiction.and,.

in.the.USA,.the.National.Fuel.Gas.Code.NFPA.

54./.ANSI.Z223.1.-.latest.edition.or.,.in.Canada,.

the.CAN/CSA-B149.1-.latest.edition.

NOTE: Flame appearance will diminish 4% per

thousand feet.

Burner Orifice Sizes

Elevation 0-4500 feet ( 0-1372 meters)

Model

Nat.Gas

drill size (inches)

Propane

drill size (inches)

LSM40-2 .1405" (#28)*

• H2286

.086" (#44)*

• H2287

LSM45-2

.161" (#20)*

• H2288

.093" (#42)*

• H4816

Table 4

* Standard size installed at factory

• Part /Cat. Number

Gas Valve Diagrams

See.

Figure 1.for.Millivolt.models.and Figure 2.

For.Electronic.Models.

Figure 1

- SIT Millivolt Gas Valve

H

I

LO

W

TPTH

TP

TH

PIL

OT

PILOT O

N

i

t

OF

F

Hi / Lo

Variable Flame

Height Adjustment

Manifold

Pressure

Gauge Port

Inlet Pressure

Gauge

Port

Main Gas

Control Knob

Off / Pilot / On

Pilot

Adjustment

Screw

IN

OU

T

Gas Supply Inlet

Gas Outlet to Burner

Test. gauge. connections. are. provided. on. the.

front.of.the.millivolt.and.electronic.gas.control.

valve.(identified.IN.for.the.inlet.and.OUT.for.the.

manifold.side)...

Propane.tanks.are.at.pressures.that.will.cause.

damage.to.valve.components...Verify.that.the.

tanks.have.step.down.regulators.to.reduce.the.

pressure.to.safe.levels.

Gas Pressure - All Models

Tables 2 and 3 show.the.appliances'.inlet.and.

manifold.gas.pressure.requirements:

Inlet Gas Supply Pressure

(all models)

Fuel #

Minimum

Maximum

Natural Gas

5.5" WC

(1.37 kPa)

10.5" WC

(2.61 kPa)

Propane

11.0" WC

(2.74 kPa)

13.0" WC

(3.23 kPa)

Table 2

Manifold Gas Supply Pressure

(all models)

Fuel #

Low

High

Natural

Gas

(Lo) 2.2" WC

(.55 kPa)

(Hi) 3.5" WC

(.87 kPa)

Propane (Lo) 6.3" WC

(1.57 kPa)

(Hi) 10.0" WC

(2.49 kPa)

Table 3

These.appliances.must.not.be.connected.to.a.

chimney.or.flue.serving.a.separate.solid.fuel.

burning.appliance.

REQUIREMENTS FOR THE COMMON-

WEALTH OF MASSACHUSETTS

These.fireplaces.are.approved.for.installation.in.

the.US.state.of.Massachusetts.if.the.following.

additional.requirements.are.met:

•. Install. this. appliance. in. accordance. with.

Massachusetts.Rules.and.Regulations.248.

C.M.R..

•. Installation.and.repair.must.be.done.by.a.

plumber.or.gas.fitter.licensed.in.the.Com-

monwealth.of.Massachusetts.

•. The.flexible.gas.line.connector.used.shall.

not.exceed.36.inches.(92.centimeters).in.

length.

•. The.individual.manual.shut-off.must.be.a.

T-handle.type.valve.

Massachusetts Horizontal Vent Requirements

In the Commonwealth of Massachusetts,

horizontal terminations installed less than

seven (7) feet above the finished grade

must comply with the following additional

requirements:

•. A. hard. wired. carbon. monoxide. detector.

with.an.alarm.and.battery.back-up.must.be.

installed.on.the.floor.level.where.the.gas.

fireplace.is.installed...The.carbon.monoxide.

detector.must.comply.with.NFPA.720,.be.

ANSI/UL.2034.listed.and.be.ISA.certified.

•. A.metal.or.plastic.identification.plate.must.

be.permanently.mounted.to.the.exterior.of.

the.building.at.a.minimum.height.of.eight.(8).

feet.above.grade.and.be.directly.in.line.with.

the.horizontal.termination...The.sign.must.

read,.in.print.size.no.less.than.one-half.(1/2).

inch.in.size,.GAS.VENT.DIRECTLY.BELOW...

KEEP.CLEAR.OF.ALL.OBSTRUCTIONS.

NEW YORK CITY, NEW YORK (MEA)

Installation.of.these.fireplaces.are.approved.for.

installation.in.New.York.City.in.the.US.state.

of.New.York.

Hi / Lo

Variable Flame

Height

Adjustment

Gas Supply Inlet

Manifold

Pressure

Gauge Port

Inlet Pressure

Gauge Port

Pilot

Adjustment

Screw

Gas Outlet to Burner

HI

LO

Figure 2

- SIT Electronic Gas Valve