Warning, Avertissement – Milwaukee LSM40MP-2 User Manual

Page 9

Advertising
background image

NOTE:.DIAGRAMS.&.ILLUSTRATIONS.ARE.NOT.TO.SCALE.

9

Left Side Front Corner of Fireplace Shown

(Right Side Requirements the Same)

Unit Being Secured By Its Nailing Flanges

To The Framing

Note: The nailing flanges, combustible members

and screw heads located in areas directly adjacent

to the nailing flanges, are ExEMPT from the 1/2”

clearance to combustible requirements for the

firebox outer wrapper. Combustible framing may be

in direct contact with the nailing flanges and may

be located closer than 1/2” from screw heads and

the firebox wrapper in areas adjacent to the nailing

flanges. Frame the opening to the exact dimensions

specified in the framing details of this manual.

Unit Being Secured by Its Nailing

Flanges to the Framing

Figure 11

Unit Being Secured by Its Nailing

Flanges to the Framing

Note: The nailing flanges, combustible members

and screw heads located in areas directly adjacent

to the nailing flanges, are EXEMPT from the 1/2”

clearance to combustible requirements for the

firebox outer wrapper. Combustible framing may be

in direct contact with the nailing flanges and may

be located closer than 1/2” from screw heads and

the firebox wrapper in areas adjacent to the nailing

flanges. Frame the opening to the exact dimensions

specified in the framing details of this manual.

Use Top Flange For

1/2” Thick Drywall

Use Bottom Flange For

5/8” Thick Drywall

Front Of

Fireplace

Use Center Flange

For Flush Mount

Left Side Front Corner of Fireplace Shown

(Right Side Requirements the Same)

Unit Being Secured By Its Nailing Flanges

To The Framing

Step 3...(Page 12).Install.the.vent.system.and.

exterior.termination...

Step 4. (Page 21) Field.Wiring

a. Millivolt.and.Electronic.Appliances.

The.operating.control.switch.is.fac-

tory.installed.

b..Electronic.Appliances.–.Connect.120.

Vac.electrical.power.to.the.appliance.

receptacle..

Step 5.. (Page 22).Remove.glass.door.assem-

bly..

Step 6.. (Page 22). Make. connection. to. gas.

supply.

Step 7.. (Page 23).Verifying.appliance.opera-

tion..

Step 8.. (Page 24).Install.ceramic.panels,.logs.

and.glowing.embers.

Step 9. (Page 26).Install.glass.door.assem-

bly.

Step 10. (Page 26) Adjust. burner. to. ensure.

proper.flame.appearance.

Step 11..(Page 29) Attach.Safety.in.Operation.

Warnings.

Step 1. FRAMING

Frame.these.appliances.as.illustrated.in.Figure

12 on Page 10, unless.the.appliance.is.to.be.

installed.in.a.corner. See.Figure 13 on Page

11 .for.corner.framing.installations...All.framing.

details.must.allow.for.a.minimum.clearance.to.

combustible. framing. members. as. shown. in.

Table 5 on Page 8.

If.the.appliance.is.to.be.elevated.above.floor.

level,. a. solid. continuous. platform. must. be.

constructed.below.the.appliance.

Headers. may. be. in. direct. contact. with. the.

appliance. top. spacers. but. must. not. be. sup-

ported.by.them.or.notched.to.fit.around.them...

All.construction.above.the.appliance.must.be.

self-supporting,.

DO NOT.use.the.appliance.for.

structural.support.

The. fireplace. should. be. secured. to. the. side.

framing. members. using. the. unit's. nailing.

flanges.-.one.top.and.bottom.on.each.side.of.

the.fireplace.front.(see.Figure 11). Use.8d.nails.

or.their.equivalent.

DETAILED INSTALLATION STEPS

The.appliance.is.shipped.with.all.gas.controls.

and.components.installed.and.pre-wired..

1.. Remove.the.shipping.carton,.exposing.the.

front.glass.door.on.the.valve.access.side.

2.. Using.a.Phillips.screwdriver,.unfasten.two.(2).

screws.located.at.the.top.of.the.glass.frame.

(see Figure 49). Tilt.the.top.of.the.glass.frame.

away.from.the.unit...Lift.it.carefully.off.the.

bottom.door.track.and.set.the.door.aside,.

protecting.it.from.inadvertent.damage.

TYPICAL INSTALLATION SEQUENCE

The.typical.sequence.of.installation.is.outlined.

below.. . However,. each. installation. is. unique.

and. may. result. in. variations. to. the. steps.

described..

See.the.Page.numbers.references.in.the.follow-

ing.steps.for.detailed.procedures.

Step 1. (Page 9) Construct. the. appliance.

framing...Position.the.appliance.within.

the. framing. and. secure. with. nailing.

brackets.

Step 2. (Page 11) .Route.gas.supply.line.to.

the.right.side.

WARNING

Failure to position the parts in

accordance with these diagrams

or failure to use only parts specifi-

cally approved with this appliance

may result in property damage or

personal injury.

AVERTISSEMENT

Risque de dommages ou de

blessures si les pièces ne sont

pas installées conformément à

ces schémas et ou si des pièces

autres que celles spécifiquement

approuvées avec cet appareil sont

utilisées.

Advertising