Gas valve, Gas solid line connector gas flex line connector – Milwaukee LSM40MP-2 User Manual

Page 22

Advertising
background image

22

NOTE:.DIAGRAMS.&.ILLUSTRATIONS.ARE.NOT.TO.SCALE.

Step 5. REMOVE GLASS DOOR FRAME

Remove.glass.door.assembly...See.Removing

Glass Enclosure Panels.on.Page 26.

Step 6. CONNECTING GAS LINE

All.codes.require.a.shut-off.valve.mounted.in.

the.supply.line..The.orientation.of.the.shut-off.

valve. should. face. the. front.. .

Figure 37 . il-

lustrates.two.methods.for.connecting.the.gas.

supply...A.Sediment.Trap.is.recommended.to.

prevent.moisture.and.debris.in.gas.line.from.

damaging.the.valve.

The.flex-line.method.is.acceptable.in.the.U.S.A..

where.local.codes.permit,.however,.Canadian.

requirements.vary.depending.on.locality..Instal-

lation.must.be.in.compliance.with.local.codes...

These.appliances.are.equipped.with.a.gas.flex-

line.for.use.in.connecting.the.unit.to.the.gas.line...

See.Figure 37 for.flex-line.description...The.

flex-line.is.rated.for.both.natural.and.propane.

gas..A.manual.shut.off.valve.is.also.provided.

with.the.flex-line..

The.gas.control.valve.is.located.on.the.right.

side.of.the.unit.

When.using.solid.gas.line.connector,.access.

the.valve.by.removing.the.front.door.assembly.

on.the.valve.access.side.and.the.access.plate.

(refer to Figure 38).

The.millivolt.and.electronic.control.valve.has.a.

3/8".(10.mm).NPT.thread.gas.supply.inlet..

Bring.the.shutoff.valve.on.the.end.of.the.flex-line.

over.to.the.hard.pipe.and.tighten.with.wrenches.

from.above.through.the.firebox.opening.

Secure all joints tightly using appropriate

tools and sealing compounds (ensure propane

resistant compounds are used in propane ap-

plications). It is recommended to seal around

the gas line to prevent cold air leakage.

Piezo

Igniter

Gas Valve

ON/OFF Switch

Access Plate

Right Side

Modesty Panel

Hi-Lo

Extension Knob

Figure 38

Note: The gas supply line

must be installed in accor-

dance with building codes

by a qualified installer

approved and/or licensed

as required by the locality.

In the Commonwealth of

Massachusetts, installation

must be performed by a

licensed plumber or gas

fitter.

Gas

Valve

3/8" NPT x

Flare Fitting

3/8" Flex Tubing

3/8" Nipple

3/8" Union

3/8" Close

Nipple

3/8" Shut-off Valve

1/2" x 3/8"

Reducer

Gas

Stub

1/2" x 3/8" Flare

Shut-off Valve

Gas Solid Line Connector

Gas Flex Line Connector

*Sediment

Trap

3"

Min

Figure 37 -

GAS CONNECTION

Figure 36-

J-BOX WIRING

J-BOX/RECEPTIACLE

WIRING

120V, 60HZ, 1PH

Factory Wired

Field Wired

Junction Box

Tab Intact

Tab

Intact

n e

e r

G -

d n

u o r

G

e t i

h

W - l

a r t

u e

N 12

0

VA

C

- B

la

ck

Green

Ground

Screw

W

hi

te

Gr

ee

n

Neutral

Side of

Receptacle

Hot

Side of

Receptacle

Black

Advertising