NOTE:.DIAGRAMS.&.ILLUSTRATIONS.ARE.NOT.TO.SCALE.

15

Framing Dimensions for Roof

Inches (millimeters)

Pitch

C

D

0/12

13 in.

(330 mm)

13 in.

(330 mm)

6/12

13 in.

(330 mm)

15-1/2 in.

(394 mm)

12/12

13 in.

(330 mm)

20-1/2 in.

(541 mm)

C

D

Figure 22 - Roof Framing

Figure 24

G..Continue installation of horizontal/inclined

sections -.Continue.with.the.installation.of.the.

straight.vent.sections.in.horizontal/inclined.run.

as.described.in.Step C..Install.support.straps.

every. 3'. (914. mm). along. horizontal/inclined.

vent.runs.using.conventional.plumber’s.tape..

See Page 17, Figure 28..It is very important

that the horizontal/inclined run be maintained

in a straight (no dips) and recommend to be in

a slightly elevated plane, in a direction away

from the fireplace 1/4" per foot (20 mm per

meter) which is ideal,.through.rise.per.foot.run.

ratios.that.are.smaller.are.acceptable.all.the.way.

down.to.at.or.near.level...Use.a.carpenter’s.level.

to.measure.from.a.constant.surface.and.adjust.

the.support.straps.as.necessary..

It is important to maintain the required clear-

ances to combustibles: 1" (25 mm) at all sides

for all vertical runs; and 3" (76 mm) at the top,

1" (25 mm) at sides, and 1" (25 mm) at the

bottom for all horizontal/inclined runs.

H..Frame roof opening -.Identify.location.for.

vent.at.the.roof..Cut.and/or.frame.opening.per.

Roof.Framing.Chart.(Figure 22)...

One.method.of.support.is.by.utilizing.field.pro-

vided.support.straps.(conventional.plumber's.

tape)..Secure.the.plumber's.tape.to.the.framing.

members.with.nails.or.screws. Strap.the.tape.

around.the.vent,.securing.the.ends.of.the.tape.

to.the.framing..If.desired,.sheet.metal.screws.#6.

x.1/2".length.may.be.used.to.secure.the.support.

straps.to.the.vent.pipe...See.Figure 20.

F. Change vent direction to horizontal/inclined

run -.At.transition.from.or.to.a.horizontal/inclined.

run,.install.the.SV8.E45.and.SV8.E90.elbows.in.

the.same.manner.as.the.straight.vent.sections...

The.elbows.feature.a.twist.section.to.allow.them.

to.be.routed.about.the.center.axis.of.their.initial.

collar.section.to.align.with.the.required.direc-

tion.of.the.next.vent.run.element..Twist elbow

sections in a clockwise direction only so as

to avoid the possibility of unlocking any of

the previously connected vent sections..See.

Figure 19 on Page 14 and Figure 21.

Figure 21

If.the.vent.system.extends.more.than.5.feet.(1.5.

m).above.the.roof.flashing,.stabilizers.may.be.

necessary..Additional.screws.may.be.used.at.

section.joints.for.added.stability..Guide.wires.

may.be.attached.to.the.joint.for.additional.sup-

port.on.multiple.joint.configurations.

Swivel Joint

(360° swivel)

SV8E45

(45° Elbow)

Swivel Joint

(360° swivel)

SV8E90

(90° Elbow)

6"

(153mm)

10"

(254mm)

K. Install the vertical termination - The.

final.step.involves.installation.of.the..Vertical.

Termination...Extend.the.vent.sections.to.the.

height.as.shown.in.the."Vertical.vent.termina-

tion.section".on.Page 6...The.SV8VTR.Vertical.

Termination.(

Figure 24).can.be.installed..in.the.

exact.same.fashion.as.any.other.Secure Vent™.

section...Align.the.termination.over.the.end.of.

the.previously.installed.section,.adjusting.the.

radial.alignment.until.the.four.locking.dimples.

of.the.termination.are.aligned.with.the.inlets.of.

the.four.incline.channels.of.the.last.vent.section...

Push.the.termination.down.until.it.fully.engages,.

then.twist.the.termination.clockwise.running.the.

dimples.down.and.along.the.incline.channels.

until.they.seat.at.the.end.of.the.channels.

I..Install the roof flashing - Extend.the.vent.

sections.through.the.roof.structure..Install.the.

roof.flashing.over.the.vent.section.and.posi-

tion.such.that.the.vent.column.rises.vertically.

(use.carpenters.level).(Figure 23)..Nail.along.

perimeter.to.secure.flashing.or.adjust.roofing.

to.overlap.the.flashing.edges.at.top.and.sides.

only.and.trim.where.necessary..Seal.the.top.

and.both.sides.of.the.flashing.with.waterproof.

caulking.

J. Install the storm collar -.Install.the.storm.

collar,. supplied. with. the. flashing,. over. the.

vent/flashing. joint. (see. Figure 23). . Loosen.

the.storm.collar.screw..Slide.collar.down.until.

it.meets.the.top.of.the.flashing..Tighten.the.ad-

justing.screw..Apply.non-combustible.caulking.

or.mastic.around.the.circumference.of.the.joint.

to.provide.a.water.tight.seal.

Figure 23

Storm

Collar

Storm

Collar

Flashing

Advertising