1 [alarm in] terminal (supports channels 1 - 16), 2 [alarm reset] input terminal, 3 [clock reset in] terminal – JVC VR-716E User Manual

Page 10: 4 [series rec in] terminal, 5 [ext rec in] terminal, 6 [com] common ground terminal, 7 [series rec out] terminal, 8 [clock reset out] terminal, 9 [warning out] terminal, 0 [alarm rec out] terminal

Advertising
background image

10

COM

EXT REC

OUT

REC

SER

IN

OUT

RST

CLK

OUT

WAR

IN

COM

RST

OUT

16

14

12

10

8

6

4

2

15

13

11

9

7

5

3

1

ALARM

1

ALARM IN

2

ALARM RESET

3

CLOCK RESET IN

4

SERIES REC IN

5

EXT REC IN

6

COM

7

SERIES REC OUT

8

CLOCK RESET OUT

9

WARNING OUT

0

ALARM REC OUT

COM

EXT REC

OUT

REC

SER

IN

OUT

RST

CLK

OUT

WAR

IN

COM

RST

OUT

16

14

12

10

8

6

4

2

15

13

11

9

7

5

3

1

ALARM

13 16

9 12

5 8

1 4/ 16

EE OUT

SCSI

RS-232C

UPS

2

1

AUDIO OUT

VIDEO OUT

2

1

LAN

AUDIO IN

VIDEO IN

THRU OUT

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

AVIS:RISQUE DE CHOC

ELECTRIQ

AC IN

(220V–240V )

SIGNAL GND

1 [ALARM IN] Terminal (Supports Channels 1 - 16)

Terminal that accepts input signals to start alarm or sensor
recording.

2 [ALARM RESET] Input Terminal

Terminal that accepts signals to stop recording during alarm
or sensor recording.

3 [CLOCK RESET IN] Terminal

For connection to a master clock or the [CLOCK RESET
OUT] terminal of other devices. This equipment can be set
to a master clock or the clock of other devices upon the
input of clock reset signals.
The clock in VR-716 will be reset as follows upon the input
of clock reset signals:
• When the value is 29 seconds or less, this will be reset to

00 seconds with the minute value unchanged.

• When the value is 30 seconds and above, this will be

reset to 00 seconds with the minute rounded to the next
higher value.

☞ Page 61 ‘Series Recording Using 2 or More VR-716 Re-

corders’

4 [SERIES REC IN] Terminal

Series recording will start upon the input of [SERIES REC
OUT] signals. This is the terminal that accepts the series
recording signals of other VR-716s when multiple sets of
VR-716 are used.
☞ Page 61 ‘Series Recording Using 2 or More VR-716 Re-

corders’

Getting Started (continued)

Names and Functions (Signal In/Out Terminal)

5 [EXT REC IN] Terminal

Starts recording automatically upon receiving external sig-
nals when the “EXT REC MODE” is set as “TRIGGER” or
“MANUAL”.
☞ Page 25 ‘OPERATION/EXT REC Menu’

☞ Page 61 ‘Activation of Recording Via External Signals’

6 [COM] Common Ground Terminal

This is a common ground terminal. For connection to the
signal ground terminal of other devices.

7 [SERIES REC OUT] Terminal

Outputs signals when the remaining hard disk space is 1 %
or less.
However, there will be no signal output in the following cir-
cumstances:
• When the “SERIES REC” item is set as “OFF” in the menu.
☞ Page 25 ‘OPERATION/EXT REC Menu’

☞ Page 61 ‘Series Recording Using 2 or More VR-716 Re-

corders’

8 [CLOCK RESET OUT] Terminal

Terminal for output of clock reset signals. Signals are out-
put in the following cases:
When the internal clock of VR-716 turns 00:00 or 12:00.
☞ Page 61 ‘Series Recording Using 2 or More VR-716 Re-

corders’

9 [WARNING OUT] Terminal

Outputs signals during hard disk malfunction or error oc-
currence. (

☞ Page 105)

0 [ALARM REC OUT] Terminal

Outputs signals when VR-716 is in the Alarm Recording or
Sensor Recording mode.

(Rear)

CAMERA 1, 3, 5,
7, 9, 11, 13, 15

CAMERA 2, 4, 6,
8, 10, 12, 14, 16