Installation and preparation, System connection (when connecting 16 cameras), Example – JVC VR-716E User Manual

Page 14: Video in, Video in] [audio in] ups [alarm in] [com

Advertising
background image

14

System Connection (When Connecting 16 Cameras)

Installation and Preparation

• Please consult the sales outlet from which this equipment is purchased on the type of UPS

units that are compatible with this equipment.

• Consult the outlet from which this equipment is purchased on the types of usable external

HDDs.

• Do not connect CCU’s [CAMERA INPUT] to VR-716’s [VIDEO IN]. Doing so may damage the input circuit of VR-716.
• When this equipment is connected to CCU, “NO VIDEO IN ** INPUT (E-03)” will be displayed on the screen if error occurs

during signal input. (** indicates the Camera No.) Recording cannot be properly performed in such a state at both the camera
for which error has occurred as well as at other properly functioning cameras. In this case, set the REC MODE of the camera
channel for which error has occurred to “OFF” on the menu, and eliminate the cause of the error immediately.
☞ Page 24 ‘REC MODE Menu’

• Turn OFF the power of all devices before connecting or disconnecting.
• For channels that are not connected to cameras, set them to “OFF” on the “REC MODE” Menu.

☞ Page 24 ‘REC MODE Menu’

• When [THRU OUT] is connected with the [BNC] connector, the built-in 75 ¸ terminal will be left OPEN. In this case, connect

a 75 ¸ terminal to the last device.

• For connection of devices other than VR-716, please refer to the respective instruction manuals for details.
• Please refer to Page 73 ‘Connecting to a PC’ for connection with computers.

Caution

Notes

Connection with up to 16 cameras is possible with VR-716’s switcher.

• Perform recording/playback by connecting to 16 cameras.
• Checking recorded images at Monitor 1 and live camera images on Monitors 2 ~ 5 at the same time.
• Execution of alarm recording upon receiving signals from the alarm sensor.

Camera 2

Camera 16

Control (Communication) Terminal

AC 220 V - 240 V

Output

Alarm Sensor

Monitor 5

Monitor 1

Monitor 2 Monitor 3 Monitor 4

Computer

External Hard Disk

Drive

Power Cord

(Supplied with this equipment)

AC 220 V - 240 V Output

<Example>

•••••••

COM

EXT REC

OUT

REC

SER

IN

OUT

RST

CLK

OUT

WAR

IN

COM

RST

OUT

16

14

12

10

8

6

4

2

15

13

11

9

7

5

3

1

ALARM

13 16

9 12

5 8

1 4/ 16

EE OUT

SCSI

RS-232C

UPS

2

1

AUDIO OUT

VIDEO OUT

2

1

LAN

AUDIO IN

VIDEO IN

THRU OUT

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

AVIS:RISQUE DE CHOC
ELECTRIQ

[VIDEO IN]

[VIDEO IN]

[AUDIO IN]

UPS

[ALARM IN]

[COM]

AC IN

(220V–240V )

SIGNAL GND

Camera 1

AC 220 V - 240 V

AC 220 V - 240 V

50 Hz/60 Hz

Advertising