Print darkness – SATO CT410 User Manual

Page 101

Advertising
background image

Print Darkness

Command Structure

<ESC>#Eab

a

=

Print Darkness Range (A thru F)

b

=

Print darkness value (1 thru 5)

Example:

<ESC>#E2A

Placement:

Must be placed immediately after <ESC>A and
immediately before <ESC>Z in its own separate data stream

Default:

Value set in printer using the <ESC>PG Printer Setting

Command Function

To specify a new print darkness setting. This command allows
software control of the darkness setting for unique media and ribbon
combinations.

Input to Printer

<ESC>A
<ESC>#EA2
<ESC>Z

Printer Output

There is no printer output for this command.

Special Notes

1. This becomes the new setting in the printer configuration for all

subsequent print jobs, unless changed. The setting is stored in
non-volatile memory and is not affected by cycling power.

2. The allowable Print Darkness Level setting is “A” for SATO

ThechoTherm direct thermal media and “B” for SATO
TechnoTherm coated thermal transfer media.

Section 4. Programming Reference

SATO CT Series Printers

9001069

A

Page 4-57

Advertising
This manual is related to the following products: