SATO CT410 User Manual

Page 113

Advertising
background image

Printer Output

Special Notes

1. The value specified for Print Quantity should be equal to the

number of different sequential values desired multiplied by the
number of repeats specified.

Example:

To print 2 sets each of the numbers 1001-1025 on separate
labels, we need 50 total labels. The commands would be as
follows:

<ESC>A
<ESC>H0100<ESC>V0100<ESC>F0002+001<ESC>XM1001
<ESC>Q50
<ESC>Z

2. It is necessary to specify the print position for each sequential field

on a label.

3. Up to eight different sequential fields can be specified per label.

4. This command ignores alpha characters in the sequential number

field for decimal counting after the last hexidecimal (F) character.

5. This command can not be used with the following commands:

Copy Image
Reverse Image
Line Feed

6. The “a” field can be omitted. If it is omitted, the sequential

numbering will be a decimal count.

Section 4. Programming Reference

SATO CT Series Printers

9001069

A

Page 4-69