SRS Labs Projector 8953H User Manual

Page 99

Advertising
background image

99

4. Management with Web browser software

4.6 Command Control via the Network (Continued)

Command Format
Command formats differ among the different communication ports.

● TCP #23

You can use the RS-232C commands without any changes. The reply data

format is the same as the RS-232C commands. However, the following reply

will be sent back in the event of authentication failure when authentication is

enabled.

Header

Data length

RS-232Ccommand

Check Sum Connection

ID

0x02

0x0D

13 bytes

1 byte

1 byte

Reply

Error code

0x1F

0x04

0x00

<Reply in the event of an authentication error>

Header

→ 0x02, Fixed

Data length

→ RS-232C commands byte length (0x0D, Fixed)

RS-232C command → RS-232C commands that start with 0xBE 0xEF

(13 bytes)

Check Sum

→ This is the value to make zero on the addition of the

lower 8 bits from the header to the checksum.

Connection ID

→ Random value from 0 to 255 (This value is attached

to the reply data)

● TCP #9715

Send Data format

The following formatting is added to the header (0x02), Data length (0x0D),

Checksum (1byte) and Connection ID (1 byte) of the RS-232C commands.

Advertising