Atv58 trx type f drive controllers, Altivar, 58 trx ac drives – Schneider Electric ALTIVAR 58 TRX User Manual

Page 13: Type f drive controllers, Atv58 trx type f product family

Advertising
background image

Altivar

®

58 TRX AC Drives

Type F Drive Controllers

13

09/2003

©

2000–2003 Schneider Electric All Rights Reserved

ATV58 TRX TYPE F DRIVE CONTROLLERS

The ATV58 TRX family of adjustable-frequency AC drive controllers is used
to control three-phase asynchronous motors. ATV58 TRX Type F models
contain an ATV58 TRX Type H drive controller packaged in a compact Type
12 enclosure. They are for use in mechanical rooms, OEM equipment, and
factory floor applications requiring a local load break switch and input line
fusing. The following models are available:

• 1 to 7.5 hp (0.75 to 5.5 kW), 400/460 Vac, three-phase input

• ½ to 3 hp (0.37 to 2.2 kW), 200/240 Vac, single-phase input

• 2 to 3 hp (1.5 to 2.2 kW), 200/240 Vac, three-phase input

Each ATV58 TRX Type F drive controller contains:

• A Vario load break switch, input line fuses, and an ATV58 TRX drive

controller

• Start Stop push buttons

• A manual speed potentiometer mounted on the front of the enclosure

• Space for one additional 16-mm operator

• Four conduit openings that are closed with plugs

• A transparent plastic door to allow viewing of status LEDs and a

separately supplied keypad

All ATV58 TRX communications and I/O options can be used in the Type F
drive controllers. The Type F drive controllers can be used on constant or
variable torque applications. The ratings are shown in the tables below.

200 Vac -10% / 240 Vac +10% at 50/60 Hz ±5%, Single-Phase Input with 3-Phase Output

Frame
Size

Drive Controller
Catalog Number

Motor Power

Rated
Output Current

Transient
Output Current

kW

HP

A

A

1

ATV58EU09M2FZU

0.37

0.5

2.3

3.1

1

ATV58EU18M2FZU

0.75

1

4.1

5.6

2

ATV58EU29M2FZU

1.5

2

7.8

10.6

3

ATV58EU41M2FZU

2.2

3

11

15

200 Vac -10% / 240 Vac +10% at 50/60 Hz ±5%, 3-Phase Input with 3-Phase Output

Frame
Size

Drive Controller
Catalog Number

Motor Power

Rated
Output Current

Transient
Output Current

kW

HP

A

A

2

ATV58EU29M2FZU

1.5

2

7.8

10.6

3

ATV58EU41M2FZU

2.2

3

11

15

400 Vac -10% / 460 Vac +10% at 50/60 Hz ±5%, 3-Phase Input with 3-Phase Output

Frame
Size

Drive Controller
Catalog Number

Motor Power

Rated
Output Current

Transient
Output Current

kW

HP

A

A

2

ATV58EU18N4FZU

0.75

1

2.3

3.1

2

ATV58EU29N4FZU

1.5

2

4.1

5.6

2

ATV58EU41N4FZU

2.2

3

5.8

7.9

3

ATV58EU54N4FZU

3

7.8

10.6

3

ATV58EU72N4FZU

4

5

10.5

14.3

3

ATV58EU90N4FZU

5.5

7.5

13

17.7

For dimensions, see page 122; for wiring diagrams, see pages 111 and 112.

Power indicated is for a switching frequency between 0.5 and 4 kHz, and at steady state. For switching
frequency between 8 and 16 kHz, use the next largest size drive controller. (For example, for 2 hp, order drive
controller ATV58EU41M2FZU.) If the duty cycle (that is, the drive controller run time) does not exceed 60% (36
second maximum for a 60 second cycle), this is not necessary.

For 60 seconds.

A line reactor (3% minimum) must be used with this drive controller.