S6=n

This register denotes the wait time, in seconds, before a blind 
dial (no dial tone detection). Cannot be configured in 
AceManager. 

n=2‐10 seconds

S8=n

Whenever a dial command contains the comma character, the 
contents of this register specify the pause time for each comma. 
Cannot be configured in AceManager. 

n=0‐255

S9=n

Specifies the time that the received carrier must be present for 
the modem to recognize it and turn on Data Carrier Detect 
(DCD) if applicable. The implementation is entirely at the IWF 
modem. Cannot be configured in AceManager. 

n=0‐255

S10=n

Specifies the amount of time that the carrier from the remote 
modem can be lost before the modem goes on‐hook. This 
allows temporary disruptions to carrier without disconnecting. 
A setting of 255 causes the modem to disable Carrier Detect 
and presume carrier is always present. Cannot be configured 
in AceManager.

n=1‐2545

S23=[speed],[databits][parity][stop bits]

Serial line parameters. The settings take affect after reset.

speed=300 | 1200 | 2400 | 4800 | 9600 | 19200 | 38400 | 
57600 | 115200 | 230400

databits=7 or 8    (Databits MUST be 8 data bits for PPP 
mode.) 

parity=O : Odd

parity=E : Even 

parity=N : None

parity=M : Mark 

stopbits=1 | 1.5 | 2

Example: 

ATS23=19200,8N1

Sets modem to 19200, 8 databits, no parity, and 1 stop bit. 