Circuit Switch Communications

Rev 3.0B Feb.08

135

Commands Specific to the Raven 1x C3210 and C3216

The command string cannot contain any spaces, commas, the 
plus (+) symbol, or a semi‐colon (;). If an AT command needed 
for the string contains a plus or comma (for example, 
+IFC=0,0), you will need to designate a break character since 
you cannot use the standard break of ;  for the plus to be read 
and a replacement for the comma. The break and comma 
designations need to be at the end of the *PTINIT command 
and separated with commas. During the INIT sequence, the 
modem looks at the entire command before executing the AT 
command string. If there are replacement values, it will 
perform the appropriate replacement before executing the AT 
command. 

Commands Specific to the Raven 1x C3211

No special characters are needed for BREAK and comma 
though some commands will require a ‘line break’, ;AT.

Table 2-1: Example for the Raven C3210 and C3216

Command

Components

AT*PTINIT=

AT&C1S0=1$QCVAD=4%+IFC=0^0,%,^

AT*PTINIT=

Include this portion only if you will not be entering
the command using a AceManager. The
remainder of the example is the command string.

AT
All AT commands must start with “AT”.

&C1S0=1$QCVAD=4%+IFC=0^0
The string is a combination of AT Commands
limited to a maximum of 40 characters.

,% [,break]
Optional “BREAK” character to allow the use of a
command with a “+”. In the example, a “%” is used.

,^ [,comma]
Optional comma replacement character to allow
the use of a command requiring a comma. In the
example, a ^ is used.