Users manual sx – Silex technology Mini Print Server PRICOM SX-300U User Manual

Page 21

Advertising
background image

2-5

About This Product

Users Manual SX

- Do not turn off the power to PRICOM while it is initializing to factory default.
- When PRICOM is turned on again after factory default is completed, do not push the pushbutton

switch.

<Bottom>
Ethernet Address

The Ethernet (MAC) Address of the device is found on the bottom. The last 6 digits are PRICOM’s
serial number.

- If the Ethernet Address is 00:80:92:18:0E:1A (noted as 008092180E1A) then PRICOM’s serial

number is 180E1A.

<Restore Factory default>
1. Please verify that AC adapter is not connected to PRICOM.
2. While pushing the push switch, connect the AC adapter to the power supply connector of PRICOM.
Shortly after a power is supplied, all of the Light Emitting Diodes will light and then some will turn off.
3. Continuing pushing (about 5 seconds) — when the restoration starts all of the Light Emitting Diodes
will light. When the status LED lights, release the push switch.

NOTE

Push Switch

TIP

- Do not turn off the printer until the printing of self-test/configuration settings has finished.
- The printer must have an internal font for the self-test/configuration settings to print.

<Self diagnostic/ Configuration Printing>
1. Verify that AC adapter is not connected to PRICOM.
2. Verify that the printer is connected and ready to print.
3. Verify that the printer is powered on.
4. While holding the push switch, plug in the power supply. Status LED (Orange), Link LED (Green), InfraLED
(Green) will light.
5. Hold the push switch (for about 30 seconds). The self test and configuration will then begin.

TIP

Advertising