Seagate Fibre Channel Interface User Manual

Page 166

Advertising
background image

152

Fibre Channel Interface Manual, Rev. D

35

00

Enclosure services failure

35

01

Unsupported enclosure function

35

02

Enclosure services unavailable

35

03

Enclosure services transfer failure

35

04

Enclosure services transfer refused

37 00 Parameter

rounded

3F 01 Microcode

changed

3F

02

Changed operating definition

3F

05

Device identifier changed

3F

91

WWN mismatch, ETF WWN is valid

40 01 DRAM

parity

error

42 00 Power-on

or

self-test

failure

43

00

Message reject error

44 00 Internal

target

failure

45

00

Select or reselect failure

47 00 Interface

error

When the ASC and ASCQ are 47 and 00 respectively, the Sense Key Specific field of the Extended

Sense Data has the meaning defined below. Note that more than one bit may be set.

Byte 16:
Bit 7 - Invalid destination ID
Bit 6 - Invalid source ID
Bit 5 - Invalid frame type
Bit 4 - Invalid f_ctl
Bit 3 - Invalid sequence ID
Bit 2 - Invalid df_ctl
Bit 1 - Invalid sequence count
Bit 0 - Invalid 0x_id

Byte 17:
Bit 7 - Running disparity error
Bit 6 - CRC error
Bit 5 - Payload still coming after transfer count went to 0, or invalid primitive detected before EOF.
Bit 4 - EOFa — ‘abort’ detected as EOR
Bit 3 - Invalid EOF (EOFni EOFdti)
Bit 2 - Unsupported EOF
Bit 1 - Unsupported Class (Class 1 or 2 SOF primitive detected)
Bit 0 - Invalid R_CTL

48

00

Initiator detected error

49

00

Invalid message

4E

00

Overlapped commands attempted

Table 93:

Error codes for bytes 12 and 13 of sense data (values are in hexadecimal) (Continued)

Byte 12

(ASC)

Byte 13
(ASCQ)

Description