E 210) – Seagate Fibre Channel Interface User Manual

Page 323

Advertising
background image

Fibre Channel Interface Manual, Rev. D

309

12.47.3

Diagnostic page–Send Diagnostic

The Diagnostic page instructs the drive to turn the drive fault LED on or off. This page is used only by the Send
Diagnostic command (see Table 210).

Field definitions (listed alphabetically)

Page Code
A0h

Diagnostic page-Send Diagnostic command page code.

Page Length
000Ah

The length (in bytes) of the Diagnostic—Send Diagnostic page.

SBDL (Set Bad Device Light)
1

Turn on the drive fault LED.

0

Turn off the drive fault LED.

Table 210: Diagnostic page–Send Diagnostic command

Bit

Byte

7

6

5

4

3

2

1

0

0

Page Code (A0h)

1

Reserved

2

(MSB)

Page Length (0002h)

3

(LSB)

4

Reserved

5

Reserved

SBDL

Table

number

210

210

210