189

Table 121 summarizes the Log Select Command field settings used when updating the cumulative/threshold value settings
and the resulting action that will occur based on these field settings.

The Log Select and Log Sense commands use the same log page format. See Section 12.10.

Table 121: Log Select Command field setting summary

PCR

PC

Parameter

List Length

Resulting action

1

xx

0

All cumulative counter and threshold log page values will be set to “zero” on all

log pages.

0

11

0

All cumulative counter log page values will be set to “zero” on all log pages.

0

10

0

All threshold log page values will be set to “zero” on all log pages.

0

01

nn

The cumulative counter for a specific parameter code will be set to the stipu-

lated value on a specified log page as found in the Log Parameter Page data.

0

00

nn

The threshold for a specific parameter code will be set to the stipulated value

on a specified log page as found in the Log Parameter Page data.