Fibre Channel Interface Manual, Rev. D

205

12.10.6

Factory Log page (code 3Eh)

Log Page code 3Eh specifies factory status parameters.

Field definitions (listed alphabetically)

Parameter Code

0000h

Power-on Time. The number of drive power-on minutes. Currently, the Power-on Time parameter is the only
parameter in this Log Page that is visible to OEM/customers.

0008h

The time, in minutes, to the next scheduled interrupt for a S.M.A.R.T. measurement.

Table 137: Factory Log page