Accessing Configuration Parameters

silex

Page 29

Part Number 40183-101

• SX-550 Web Page Configuration

Using Telnet Session

To access using telnet:

1. Connect the SX-550 module’s Ethernet cable to the host computer.

2. On the Windows main page, select Start>Run. The Run window displays.

3. Type the following command, then click OK.

telnet x.x.x.x

where x.x.x.x is the IP address of the SX-550 module

The default port is 23.

4. When the connection is established, press Enter. The # prompt displays.

5. Type the password (default is ACCESS), then press Enter. The password will not echo on your

screen.

6. Press

Enter until the Local> prompt displays. No user name is necessary. You can begin configuring

the SX-550 module.
Continue to Chapter 6:
Setting Configuration Parameters.


N

OTE

: For the list of console commands, refer to Appendix A:

Console Commands.

Using Terminal Emulator through the Serial Port

To access using the serial port:

1. Attach the null modem serial cable from the DB9 serial port on the SX-550 module to the COM port

on the computer.

2. If you do not wish to cycle the SX-550 module’s power to enter the console mode, continue to

step 3.
To enter the console mode by cycling the SX-550 module’s power, press and hold the SX-550
module’s test button for at least three seconds while powering the device.

The SX-550 module will begin initializing.

3. Start a terminal emulation program, such as Windows HyperTerminal, by selecting

Start/Programs/Communications/HyperTerminal. The Connection Description window displays.

4. Type a name for the connection, then click OK. The Connect To window displays.

5. In the Connect Using list box, select a connection, then click OK. The default is COM1.

The COM Properties window displays.

6. On the Port Settings tab, select the settings shown in Table 15, then click OK.