Dip switches setup, Data transfer speed setup – Sanyo TLS-9024P User Manual

Page 31

Advertising
background image

SETTING THE RS-232C OR RS-485 DATA
TRANSFER SPEED

The VCR can be controlled by a computer connected to
the RS-232C connector. It can also be controlled
through a special controller connected to the RS-485
connector.

You must specify which connector (RS-232C or
RS-485) is used. (Refer to “Data Transfer Speed
Setup.”)

DIP Switches Setup

The DIP switches need to be set when a computer,
special controller, etc. connected to the RS-232C or
RS-485 connectors is used to control the VCR. Make
sure to turn the VCR power off before setting the DIP
switches.

SW No.

1-7: To setup the VCR address (only when using the

RS-485 connector).

œ

Switch 1 is the least significant bit (LSB) and
switch 7 the most significant bit (MSB) (Down:
0, Up: 1)

Example:

œ

If the address is 1, set switch 1 to the ON side
(up)

œ

If the address is 10, set switches 2 and 4 to
the ON side (up)

œ

If the address is 127, set all the switches to
the ON side (up)

8: Available (Not used)
9: To select the connector used. [232] side (down)

for RS-232C, [485] side (up) for RS-485.

10: To setup the termination (only when using the

RS-485 connector).
OFF side (down): Not terminated

ON side (up): Terminated

NOTE:

œ

Refer to the RS-232C and RS-485 command section
or to the special controller and/or to the computer
instruction manual.

Data Transfer Speed Setup

1

Press the MENU button until the (SET UP 3) menu
is displayed.

@@@@@@@<SET@UP@3>

öALARM@MODE@@@@@@@Y1

öALARM@SPEED@@@@@@3H

öALARM@DURATION@@@20S

öTAPE@END@MODE@@@@REW

öTAPE@END@OUT@@@@@-3M

öCLOG@DETECT.@@@@@Y

öRS-232C@@@@@@@@@@19200

2

Turn the JOG dial, until the “RS-232C” or “RS-485”
setting is flashing.

NOTE:

œ

The display will depend on the DIP switch 9
setting. When down “RS-232C” is displayed and
when up “RS-485” is displayed.

3

Turn the SHUTTLE ring to set the desired transfer
speed.

4

Press the SEARCH/AUDIO ON button to save the
setting.

RS232C 9-pin connector layout

Pin

number

Signal

Operation

Signal direction

2

RXD

Receive

data

VCR

Computer

3

TXD

Send data

VCR

Computer

7

RTS

Request

to send

VCR

Computer

5

GND

Signal

ground

The signal transmission is compatible with RS-232C
specifications.

1

2

3

4

5

6

7

8

9

10

ON

ADDRESS

ON

OFF

485

232

TERMINATE

ON

OFF

1

5

9

6

RR4Q/EX2 (TLS-9024P GB) Fri. Sept., 29/2000

30

English

Advertising