Output terminals, Sw out terminal, Tape end out terminal – Sanyo TLS-9024P User Manual

Page 33

Advertising
background image

OUTPUT TERMINALS

SW OUT Terminal

When recording, a pulse signal is output at the SW OUT
terminal.

This terminal is usually connected to the switch input
(SW IN) of devices like a camera switcher unit, or a
quad compressor.

SW OUT Terminal Output Setting

1

Press the MENU button until the (SET UP 4) menu
is displayed.

ø

The FIELD (or FRAME) setting is flashing.

@@@@@@@<SET@UP@4>

öSW@OUT

@@FIELD@@@@@@@@@01

@@TIMING@@@@@@@@FIELD

@@3H@@@@@@@@@@@@Y

öTHREAD@CHECK@@@Y

öVIDEO@LOSS@@@@@N

öREC@SPEED@@@@@@N

NOTE:

œ

If “TIMING” is set to FRAME (see step

4

),

“FRAME” will be indicated instead of “FIELD”.

2

Turn the SHUTTLE ring, to set the desired pulse
signal interval.

Available settings are:

FIELD . . . . . . 01, 02, 03, 04, 05, 10, 30 or 60 field

FRAME . . . . . 01, 02, 03, 04, 05, 10, 30 or 60

frame

3

Turn the JOG dial clockwise until the “TIMING”
setting is flashing.

4

Turn the SHUTTLE ring, to set “FIELD” or “FRAME”.

FIELD . . . . . . 1 pulse is output after each set

number of fields.

FRAME . . . . . 1 pulse is output after each set

number of frames.

5

Turn the JOG dial clockwise until the “3H” setting is
flashing.

6

Turn the SHUTTLE ring, to set the desired “3H”
mode.

Y . . . . . . . . . . When recording in 3-hour mode,

a pulse signal is output.

N . . . . . . . . . . When recording in 3-hour mode,

a pulse signal is not output.

7

Press the SEARCH/AUDIO ON button to save the
settings.

TAPE END OUT Terminal

œ

During recording, when the end of the tape is
reached or when the tape counter reading indicates 2
hours 57 minutes or more, the output becomes 0V
(Low).

œ

To reset the output, press the STOP or EJECT
button.

œ

During autorepeat recording, when the end of the
tape is reached, the output becomes 0V (Low) for
about 2 seconds only.

TAPE END OUT Terminal Output Setting

1

Press the MENU button until the (SET UP 3) menu
is displayed.

@@@@@@@<SET@UP@3>

öALARM@MODE@@@@@@@Y1

öALARM@SPEED@@@@@@3H

öALARM@DURATION@@@20S

öTAPE@END@MODE@@@@REW

öTAPE@END@OUT@@@@@-3M

öCLOG@DETECT.@@@@@Y

öRS-232C@@@@@@@@@@19200

2

Turn the JOG dial, until the “TAPE END OUT”
setting is flashing.

3

Turn the SHUTTLE ring, to select the desired output
mode.

–3M . . . . . . . The output becomes 0 V (Low)

when the tape counter reaches
“2

H

57

M

00

S

” and/or when the

tape reaches the end.

END . . . . . . . The output becomes 0 V (Low)

when the tape reaches the end.

4

Press the SEARCH/AUDIO ON button to save the
setting.

5V (H)

0V (L)

(Output impedance: 5.7 k

)

FIELD: 20 msec.
FRAME: 5 msec.

Tape end or 2

H

57

M

00

S

5V (H)

0V (L)

(Output impedance: 5.7 k

)

Output reset

RR4Q/EX2 (TLS-9024P GB) Fri. Sept., 29/2000

32

English