B-14

S

UPER

S

ERVER 6014P-8/6014P-8R/6014P-82R/6014P-82 User's Manual

Rebuilding Arrays

Note 1: Rebuilding applies to Fault Tolerant arrays (RAID 1) only.

If an array build process (or initialization) is interrupted or critical with

one member missing, you must perform a rebuild to optimized its function-

ality. For a critical array rebuild operation, the optimal drive is the source

drive.

Note 2: If no spare array exists and a hard disk drive fails, you need to

create a spare before you can rebuild an array.

To Rebuild an array:

1. From the Main Menu, select Manage Arrays. From the list of arrays,

select the array you want to rebuild.

2. Press Ctrl+R to rebuild.

6. Press Enter.

7. Read the warning message as shown on the screen below.

8. Make sure that you have selected the correct disk drives to initialize.

If correct, type Y to continue.