ERVER 6014P-8/6014P-8R/6014P-82R/6014P-82 User's Manual

GLAN Enable/Disable

Change the setting of jumper JPL1

to enable or disable the LAN ports

( G L A N 1 / 2 o r J L A N 1 / 2 ) o n t h e

serverboard. See the table on the

right for jumper settings. The de-

fault setting is enabled

Jumper

Position

Pins 1-2
Pins 2-3

Definition

Enabled

Disabled

GLAN

Enable/Disable

Jumper Settings

(JPL1)

5-9

Jumper Settings

Explanation of
Jumpers

T o m o d i f y t h e o p e r a t i o n o f t h e

serverboard, jumpers can be used

t o c h o o s e b e t w e e n o p t i o n a l

settings. Jumpers create shorts

between two pins to change the

function of the connector. Pin 1 is

identified with a square solder pad

on the printed circuit board. See

the serverboard layout pages for

jumper locations.

N o t e : O n t w o p i n j u m p e r s ,

"Closed" means the jumper is on

and "Open" means the jumper is

off the pins.

Connector

Pins

Jumper

Cap

Setting

Pin 1-2 short

3 2 1

3 2 1

CMOS Clear

JBT1 is used to clear CMOS (which will also clear any passwords). In-

stead of pins, this jumper consists of contact pads to prevent accidentally

clearing the contents of CMOS.

To clear CMOS,

1) First power down the system and unplug the power cord(s)

2) With the power disconnected, short the CMOS pads with a metal object

such as a small screwdriver

3) Remove the screwdriver (or shorting device)

4) Reconnect the power cord(s) and power on the system.

Note: Do not use the PW_ON connector to clear CMOS.