Installation

Pre-Installation Inspection

Upon delivery, visually inspect the packaging and

portions of the product visible through the packaging

for shipping damage. If the package or product is

damaged, or if signs of possible damage are evident,

have the carrier note the condition on the shipping

papers before the shipping receipt is signed, or advise

the carrier of the condition as soon as it is discovered.
Remove the packaging as soon as possible and check

the items listed on the packing list. Advise the carrier

of any damaged or missing articles as soon as possible.

A written claim should be filed with the carrier

immediately if articles are damaged or missing.

IMPORTANT: Remove the shipping tape from the
two backdraft dampers located in the exhaust
outlet.

IMPORTANT: Warranty is void unless tumbler is
installed according to instructions in this manual.
Installation should comply with minimum
specifications and requirements detailed in this
manual and with applicable local gas fitting
regulations, municipal building codes, water supply
regulations, electrical wiring regulations, and any
other relevant statutory regulations. Due to varied
requirements, applicable local codes should be
thoroughly understood and all pre-installation
work arranged for accordingly.

IMPORTANT: Keep tumbler area clear and free
from combustible materials, gasoline and other
flammable vapors and liquids.

Materials Required (Obtain Locally)

All Models

One fused disconnect switch or circuit
breaker.

Gas Models

One gas shut-off valve for gas service
line to each tumbler.

Steam Models One steam shut-off valve for steam

service line to be connected upstream of
solenoid steam valve.
Two steam shut-off valves for each
condensate return line.
Flexible steam hoses with a 125 psig
(pounds per square inch gauge)
(8.79 kg/sq. cm) working pressure for
connecting steam coils. Refer to

Figure 15

for sizing and connection

configurations.
Two steam traps for steam coil outlet to
condensate return line.
Two vacuum breakers for condensate
return lines.