Figure 7, Remove screw plug from inside pressure tap, Figure 8 – Speed Queen Drying Tumblers none User Manual

Page 26: Figure 7 . re, Refer to figure 8, How to adjust gas valve governor/regulator

Advertising
background image

Installation

70256801

24

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Figure 7

How to Adjust Gas Valve Governor/Regulator

1. Check gas injector (manifold) pressure as

follows. Refer to Figure 7.

2. Remove screw plug from inside pressure tap.
3. Connect a “U”-tube manometer (or similar

pressure gauge) to the injector (manifold)

pressure tap.

4. Start tumbler and note pressure once flame is

burning. Remove regulator cap and adjust

regulator screw until the injector pressure per

applicable table is achieved. Replace regulator

cap. Refer to Figure 6.

Figure 8

T137K

1

Burner Tube Attaching Screws

6

Spud Holder Nut

2

Burner Support Bracket

7

Spud Holder

3

Pressure Tap

8

Pressure Tap (Alternate location)

4

Gas Valve

9

Manometer

5

Gas Valve Flange

1

2

4

3

5

6

7

8

9

REQUIRED

INJECTOR

PRESSURE

T025KE1D

1

Size Stamped on Orifice

T025K

1

BURNER INJECTOR

(ORIFICE)

Advertising