background image

Adjustments

70256801

50

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

CE Marked Models

Loading door switch is factory adjusted to turn off

when the door is opened a maximum of 3 inches

(76 mm). If adjustment is needed, refer to Figure 21

and follow these steps:

1. Start tumbler, following the operating

instructions which accompanied it.

2. Slowly open loading door. Cylinder and heating

system should stop when door is open 3 inches

(76 mm) maximum.

3. Slowly close loading door while depressing start

switch or pad. Tumbler should start before

loading door is 0.5 inch (13 mm) from fully

closed.

4. If opening the loading door 3 inches (76 mm)

maximum does not stop tumbler, adjust switch.

5. Loose lower screw on switch coupler (use 2 mm

hex wrench).

6. Align screw slot with alignment marks on switch

top (switch should be closed, or on).

7. Start tumbler.
8. Prop door open 2.5 inches (63 mm).
9. Slowly rotate switch coupler counterclockwise

(viewed from above switch) until tumbler stops.

10. Tighten lower screw on switch coupler.

11. Return to step 1 to verify loading door switch

operation.